Grandaire / AIR-SOURCE HEAT PUMP

W5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 2

124 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for W5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 124 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5124 / 124
EER2 · BTU/Wh11.5–14124 / 124
HSPF2 · BTU/Wh7.8–8.1124 / 124
Cooling capacity · BTU/h22,200–25,000124 / 124
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,000124 / 124
Heating capacity at 17°F / −8.3°C · BTU/h14,100–14,900124 / 124
Heating capacity at 5°F / −15°C · BTU/h10,700–11,400124 / 124
COP at 5°F / −15°C1.9–2.16124 / 124
Equipment / loop typeHP - Split System124 / 124
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)124 / 124
Compressor stagingTwo-stage124 / 124
Connected capabilityNo124 / 124

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
W5A*36M17XA*+ furnace: WFEU060B048B*AHRI reference: 21564631817.507.80109002.08EPA 3959080 →
W5A*36M17XA*+ furnace: WFET045A036A*AHRI reference: 21564642817.508.10109002.08EPA 3959158 →
W5A*36M17XA*+ furnace: WFET070A036A*AHRI reference: 21564644517.508.10109002.08EPA 3959164 →
W5A*25M17XA*+ furnace: WFJT060B048A*AHRI reference: 21572048117.508.00112002.08EPA 3980270 →
W5A*25M17XA*+ furnace: WFJT080B048A*AHRI reference: 21572049917.508.00111002.08EPA 3980379 →
WCGL245*B*AHRI reference: 21556067617.508.10111002.06EPA 3982774 →
W5A*37M17XA*+ furnace: WFEU060B048B*AHRI reference: 21719155017.508.10111002.10EPA 4011014 →
W5A*37M17XA*+ furnace: WFET045A036A*AHRI reference: 21719155217.508.10111002.08EPA 4011016 →
W5A*37M17XA*+ furnace: WFET070A036A*AHRI reference: 21719155417.508.10111002.08EPA 4011018 →
W5A*37M17XA*+ furnace: WFET090B048A*AHRI reference: 21719155617.508.10110002.10EPA 4011047 →
W5A*37M17XA*+ furnace: WFST080B048A*AHRI reference: 21719156717.508.10111002.08EPA 4011054 →
W5A*37M17XA*+ furnace: WFEU040B036B*AHRI reference: 21719154817.508.10110002.08EPA 4497016 →
QFVA5D2417X*AHRI reference: 21869536917.507.80112002.02EPA 4683461 →
W5A*24M17XA*+ furnace: WFEU040B036B*AHRI reference: 21564368917.007.80110002.06EPA 3957310 →
W5A*24M17XA*+ furnace: WFEU060B048B*AHRI reference: 21564371617.007.80109002.06EPA 3957332 →
W5A*24M17XA*+ furnace: WFET070A036A*AHRI reference: 21564384117.008.10111002.04EPA 3957414 →
W5A*24M17XA*+ furnace: WFET090B048A*AHRI reference: 21564388017.008.10110002.04EPA 3957437 →
W5A*25M17XA*+ furnace: WFSU040B036B*AHRI reference: 21564486417.008.10112002.08EPA 3958111 →
W5A*30M14XA*+ furnace: WFET045A036A*AHRI reference: 21564524517.008.10109002.06EPA 3958354 →
W5A*30M14XA*+ furnace: WFET070A036A*AHRI reference: 21564526017.008.10109002.06EPA 3958361 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →