Goodman / AIR-SOURCE HEAT PUMP

GZV9SA6010A*

GZV9SA

33 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity52,000–54,000BTU/h

Each efficiency range summarizes published EPA records for GZV9SA6010A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 33 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1833 / 33
EER2 · BTU/Wh9.8–10.533 / 33
HSPF2 · BTU/Wh8.5–933 / 33
Cooling capacity · BTU/h52,000–54,00033 / 33
Heating capacity at 47°F / 8.3°C · BTU/h52,500–54,00033 / 33
Heating capacity at 17°F / −8.3°C · BTU/h33,40033 / 33
Heating capacity at 5°F / −15°C · BTU/h45,000–47,00033 / 33
COP at 5°F / −15°C1.8–1.933 / 33
Equipment / loop typeHP - Split System33 / 33
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)33 / 33
Compressor stagingContinuously variable33 / 33
Connected capabilityYes33 / 33

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern GZV9SA6010A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight230 lbGZV9S — product specifications · page 3 ↗
Maximum overcurrent protection40 AGZV9S — product specifications · page 3 ↗
Minimum circuit ampacity34.4 AGZV9S — product specifications · page 3 ↗
Shipping weight265 lbGZV9S — product specifications · page 3 ↗
Voltage / phase at 60 Hz208-230/1 V / phaseGZV9S — product specifications · page 3 ↗

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
AHVE60DP1300A*Cold climate designationAHRI reference: 21798914018.009.00470001.90EPA 4518385 →
AHVE60DP0300A*Cold climate designationAHRI reference: 21798926718.009.00470001.90EPA 4518514 →
CA*EA6030*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 21798928117.008.80460001.90EPA 4518479 →
CA*EA6030*3A*+ furnace: G*VT800805D*A*Cold climate designationAHRI reference: 21798928317.008.80460001.90EPA 4518515 →
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21798926917.008.80460001.90EPA 4518517 →
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21798927117.008.80460001.90EPA 4518519 →
CA*EA6030*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 21798928517.008.80460001.90EPA 4518528 →
CA*EA6030*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 21798928717.008.80460001.90EPA 4518532 →
CA*EA6030*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 21798929117.008.80460001.90EPA 4518536 →
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 21798929617.008.80460001.90EPA 4518540 →
CA*EA6030*3A*+ furnace: G*VT961005CNA*Cold climate designationAHRI reference: 21798927716.508.50460001.90EPA 4518525 →
CA*EA6030*3A*+ furnace: G*VT960804CNA*Cold climate designationAHRI reference: 21798927916.508.80460001.90EPA 4518529 →
CA*EA6030*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 21798928916.508.80460001.90EPA 4518534 →
CA*EA6030*3A*+ furnace: G*VM971005CNA*Cold climate designationAHRI reference: 21798929516.508.80460001.90EPA 4518541 →
CHPEA6030*3A*+ furnace: G*VT800805D*A*Cold climate designationAHRI reference: 21798928216.008.50450001.80EPA 4518480 →
CHPEA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21798926816.008.50450001.80EPA 4518516 →
CHPEA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21798927016.008.50450001.80EPA 4518518 →
CHPEA6030*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 21798927216.008.50450001.80EPA 4518520 →
CA*EA6030*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 21798927316.008.50460001.90EPA 4518521 →
CHPEA6030*3A*+ furnace: G*VT961005DNA*Cold climate designationAHRI reference: 21798927416.008.50450001.80EPA 4518522 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

GZV9S — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values