GZV9SA361CA*
GZV9SA
31 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GZV9SA361CA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 31 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.9–21 | 31 / 31 |
| EER2 · BTU/Wh | 11–12 | 31 / 31 |
| HSPF2 · BTU/Wh | 8.5–10 | 31 / 31 |
| Cooling capacity · BTU/h | 33,400–34,200 | 31 / 31 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–34,200 | 31 / 31 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,800–34,200 | 31 / 31 |
| Heating capacity at 5°F / −15°C · BTU/h | 31,000–34,200 | 31 / 31 |
| COP at 5°F / −15°C | 2–2.4 | 31 / 31 |
| Equipment / loop type | HP - Split System | 31 / 31 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 31 / 31 |
| Compressor staging | Continuously variable | 31 / 31 |
| Connected capability | Yes | 31 / 31 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern GZV9SA361CA*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 230 lb | GZV9S — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 25 A | GZV9S — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 21.8 A | GZV9S — product specifications · page 3 ↗ |
| Shipping weight | 265 lb | GZV9S — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | GZV9S — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 216699796 | 21.00 | 10.00 | 34200 | 2.40 | EPA 4520241 → |
CA*EA6030*3A*+ furnace: G*VT800604B*A*Cold climate designationAHRI reference: 217971000 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4518330 → |
CA*EA6030*3A*+ furnace: G*VM970803BNA*Cold climate designationAHRI reference: 217971003 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4518333 → |
CA*EA6030*3A*+ furnace: G*VS800604BUA*Cold climate designationAHRI reference: 217971004 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4518334 → |
CA*EA6030*3A*+ furnace: G*VM970804CNA*Cold climate designationAHRI reference: 216699934 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4520195 → |
CA*EA6030*3A*+ furnace: G*VM971005CNA*Cold climate designationAHRI reference: 216699932 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4520197 → |
CA*EA6030*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 216699930 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4520199 → |
CA*EA6030*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 216699928 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4520201 → |
CA*EA6030*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 216699926 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4520203 → |
CA*EA6030*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 216699924 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4520205 → |
CA*EA6030*3A*+ furnace: G*VT960804CNA*Cold climate designationAHRI reference: 216699922 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4520207 → |
CA*EA6030*3A*+ furnace: G*VT961005CNA*Cold climate designationAHRI reference: 216699920 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4520209 → |
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 216699918 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4520211 → |
AHVE48CP0300A*Cold climate designationAHRI reference: 216699916 | 19.00 | 9.20 | 33000 | 2.10 | EPA 4520213 → |
AHVE48CP1300A*Cold climate designationAHRI reference: 216699915 | 19.00 | 9.20 | 33000 | 2.10 | EPA 4520214 → |
AHVE48DP0300A*Cold climate designationAHRI reference: 216699914 | 19.00 | 9.20 | 33000 | 2.10 | EPA 4520215 → |
AHVE48DP1300A*Cold climate designationAHRI reference: 216699913 | 19.00 | 9.20 | 33000 | 2.10 | EPA 4520216 → |
AHVE60DP0300A*Cold climate designationAHRI reference: 216699912 | 19.00 | 9.20 | 33000 | 2.10 | EPA 4520217 → |
AHVE60DP1300A*Cold climate designationAHRI reference: 216699911 | 19.00 | 9.20 | 33000 | 2.10 | EPA 4520218 → |
CHPEA4830*3A*+ furnace: G*VT800604B*A*Cold climate designationAHRI reference: 217970999 | 18.20 | 9.00 | 31000 | 2.00 | EPA 4518329 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.