Goodman / AIR-SOURCE HEAT PUMP

GZV7SA6010A*

GZV7SA

37 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity52,000BTU/h

Each efficiency range summarizes published EPA records for GZV7SA6010A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 37 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1837 / 37
EER2 · BTU/Wh9.837 / 37
HSPF2 · BTU/Wh8.5–937 / 37
Cooling capacity · BTU/h52,00037 / 37
Heating capacity at 47°F / 8.3°C · BTU/h52,500–54,00037 / 37
Heating capacity at 17°F / −8.3°C · BTU/h33,40037 / 37
Heating capacity at 5°F / −15°C · BTU/h45,000–46,00037 / 37
COP at 5°F / −15°C1.8–237 / 37
Equipment / loop typeHP - Split System37 / 37
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)37 / 37
Compressor stagingContinuously variable37 / 37
Connected capabilityYes37 / 37

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern GZV7SA6010A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight236 lbGZV7S — product specifications · page 3
Maximum overcurrent protection40 AGZV7S — product specifications · page 3
Minimum circuit ampacity34.4 AGZV7S — product specifications · page 3
Shipping weight271 lbGZV7S — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseGZV7S — product specifications · page 3

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
AHVE60DP1300A*Cold climate designationAHRI reference: 21683522118.009.00460002.00EPA 3996770
AHVE60DP0300A*Cold climate designationAHRI reference: 21683531018.009.00460002.00EPA 3996771
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21683531417.008.80460002.00EPA 3996773
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21683531917.008.80460002.00EPA 3996775
CA*EA6030*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 21683534217.008.80460002.00EPA 3996785
CA*EA6030*3A*+ furnace: G*VT800805D*A*Cold climate designationAHRI reference: 21683534617.008.80460002.00EPA 3996787
CA*EA6030*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 21683535117.008.80460002.00EPA 3996789
CA*EA6030*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 21683535617.008.80460002.00EPA 3996790
CA*EA6030*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 21683536017.008.80460002.00EPA 3996792
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 21683537217.008.80460002.00EPA 3996798
CA*EA6030*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758948017.008.80460002.00EPA 4497806
CA*EA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758948217.008.80460002.00EPA 4497808
CA*EA6030*3A*+ furnace: G*VT961005CNA*Cold climate designationAHRI reference: 21683533316.508.50460002.00EPA 3996781
CA*EA6030*3A*+ furnace: G*VT960804CNA*Cold climate designationAHRI reference: 21683533816.508.80460002.00EPA 3996783
CA*EA6030*3A*+ furnace: G*VM971005CNA*Cold climate designationAHRI reference: 21683537016.508.80460002.00EPA 3996797
CA*EA6030*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 21749590916.508.80460002.00EPA 4469777
CHPEA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21683531216.008.50450001.80EPA 3996772
CHPEA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21683531716.008.50450001.80EPA 3996774
CHPEA6030*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 21683532116.008.50450001.80EPA 3996776
CA*EA6030*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 21683532416.008.50460002.00EPA 3996777

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

GZV7S — product specificationsManufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →