GZV7SA6010A*
GZV7SA
37 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GZV7SA6010A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 37 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 37 / 37 |
| EER2 · BTU/Wh | 9.8 | 37 / 37 |
| HSPF2 · BTU/Wh | 8.5–9 | 37 / 37 |
| Cooling capacity · BTU/h | 52,000 | 37 / 37 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 52,500–54,000 | 37 / 37 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 33,400 | 37 / 37 |
| Heating capacity at 5°F / −15°C · BTU/h | 45,000–46,000 | 37 / 37 |
| COP at 5°F / −15°C | 1.8–2 | 37 / 37 |
| Equipment / loop type | HP - Split System | 37 / 37 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 37 / 37 |
| Compressor staging | Continuously variable | 37 / 37 |
| Connected capability | Yes | 37 / 37 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern GZV7SA6010A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 236 lb | GZV7S — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 40 A | GZV7S — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 34.4 A | GZV7S — product specifications · page 3 ↗ |
| Shipping weight | 271 lb | GZV7S — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | GZV7S — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
AHVE60DP1300A*Cold climate designationAHRI reference: 216835221 | 18.00 | 9.00 | 46000 | 2.00 | EPA 3996770 → |
AHVE60DP0300A*Cold climate designationAHRI reference: 216835310 | 18.00 | 9.00 | 46000 | 2.00 | EPA 3996771 → |
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 216835314 | 17.00 | 8.80 | 46000 | 2.00 | EPA 3996773 → |
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 216835319 | 17.00 | 8.80 | 46000 | 2.00 | EPA 3996775 → |
CA*EA6030*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 216835342 | 17.00 | 8.80 | 46000 | 2.00 | EPA 3996785 → |
CA*EA6030*3A*+ furnace: G*VT800805D*A*Cold climate designationAHRI reference: 216835346 | 17.00 | 8.80 | 46000 | 2.00 | EPA 3996787 → |
CA*EA6030*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 216835351 | 17.00 | 8.80 | 46000 | 2.00 | EPA 3996789 → |
CA*EA6030*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 216835356 | 17.00 | 8.80 | 46000 | 2.00 | EPA 3996790 → |
CA*EA6030*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 216835360 | 17.00 | 8.80 | 46000 | 2.00 | EPA 3996792 → |
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 216835372 | 17.00 | 8.80 | 46000 | 2.00 | EPA 3996798 → |
CA*EA6030*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 217589480 | 17.00 | 8.80 | 46000 | 2.00 | EPA 4497806 → |
CA*EA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 217589482 | 17.00 | 8.80 | 46000 | 2.00 | EPA 4497808 → |
CA*EA6030*3A*+ furnace: G*VT961005CNA*Cold climate designationAHRI reference: 216835333 | 16.50 | 8.50 | 46000 | 2.00 | EPA 3996781 → |
CA*EA6030*3A*+ furnace: G*VT960804CNA*Cold climate designationAHRI reference: 216835338 | 16.50 | 8.80 | 46000 | 2.00 | EPA 3996783 → |
CA*EA6030*3A*+ furnace: G*VM971005CNA*Cold climate designationAHRI reference: 216835370 | 16.50 | 8.80 | 46000 | 2.00 | EPA 3996797 → |
CA*EA6030*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 217495909 | 16.50 | 8.80 | 46000 | 2.00 | EPA 4469777 → |
CHPEA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 216835312 | 16.00 | 8.50 | 45000 | 1.80 | EPA 3996772 → |
CHPEA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 216835317 | 16.00 | 8.50 | 45000 | 1.80 | EPA 3996774 → |
CHPEA6030*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 216835321 | 16.00 | 8.50 | 45000 | 1.80 | EPA 3996776 → |
CA*EA6030*3A*+ furnace: G*VT961205DNA*Cold climate designationAHRI reference: 216835324 | 16.00 | 8.50 | 46000 | 2.00 | EPA 3996777 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
GZV7S — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →