Goodman / AIR-SOURCE HEAT PUMP

GZV7SA2410A*

GZV7SA · source records, page 4

93 published source records · source checked Sep 21, 2026

SEER2 range16–19BTU/Wh
HSPF2 range8.5–8.8BTU/Wh
Cooling capacity23,200BTU/h

Each efficiency range summarizes published EPA records for GZV7SA2410A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 93 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1993 / 93
EER2 · BTU/Wh10.5–1193 / 93
HSPF2 · BTU/Wh8.5–8.893 / 93
Cooling capacity · BTU/h23,20093 / 93
Heating capacity at 47°F / 8.3°C · BTU/h23,20093 / 93
Heating capacity at 17°F / −8.3°C · BTU/h15,80093 / 93
Heating capacity at 5°F / −15°C · BTU/h17,00093 / 93
COP at 5°F / −15°C293 / 93
Equipment / loop typeHP - Split System93 / 93
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)93 / 93
Compressor stagingContinuously variable93 / 93
Connected capabilityNo · Yes93 / 93

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern GZV7SA2410A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight132 lbGZV7S — product specifications · page 3
Maximum overcurrent protection25 AGZV7S — product specifications · page 3
Minimum circuit ampacity22.4 AGZV7S — product specifications · page 3
Shipping weight147 lbGZV7S — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseGZV7S — product specifications · page 3

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CA*EA3022*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 21543408619.008.60170002.00EPA 3625446
CA*EA3022*3A*+ furnace: G*VT800603B*A*Cold climate designationAHRI reference: 21543408719.008.60170002.00EPA 3625447
CA*EA3022*3A*+ furnace: G*VT800803B*A*Cold climate designationAHRI reference: 21543408819.008.60170002.00EPA 3625448
CA*EA3022*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 21543408919.008.60170002.00EPA 3625449
CA*EA3022*3A*+ furnace: G*VM970803BNB*Cold climate designationAHRI reference: 21548801019.008.60170002.00EPA 3628014
CA*EA3022*3A*+ furnace: G*VC800803B*A*Cold climate designationAHRI reference: 21548801419.008.60170002.00EPA 3628018
CA*EA3022*3A*+ furnace: G*VC960403BNB*Cold climate designationAHRI reference: 21548801819.008.60170002.00EPA 3628055
CA*EA3022*3A*+ furnace: G*VC960603BNB*Cold climate designationAHRI reference: 21548801919.008.60170002.00EPA 3628056
CA*EA3022*3A*+ furnace: G*VC960803BNB*Cold climate designationAHRI reference: 21548802019.008.60170002.00EPA 3628057
CA*EA3022*3A*+ furnace: G*VC960804CNB*Cold climate designationAHRI reference: 21548802119.008.60170002.00EPA 3628058
CA*EA3022*3A*+ furnace: G*VC961005CNB*Cold climate designationAHRI reference: 21548802219.008.60170002.00EPA 3628059
CA*EA3626*3A*+ furnace: G*VM970803BNB*Cold climate designationAHRI reference: 21548802419.008.60170002.00EPA 3628061
CA*EA3626*3A*+ furnace: G*VC800803B*A*Cold climate designationAHRI reference: 21548802919.008.60170002.00EPA 3628066
CA*EA3626*3A*+ furnace: G*VC960403BNB*Cold climate designationAHRI reference: 21548803319.008.60170002.00EPA 3628070
CA*EA3626*3A*+ furnace: G*VC960603BNB*Cold climate designationAHRI reference: 21548803419.008.60170002.00EPA 3628071
CA*EA3626*3A*+ furnace: G*VC960803BNB*Cold climate designationAHRI reference: 21548803519.008.60170002.00EPA 3628072
CA*EA3626*3A*+ furnace: G*VC960804CNB*Cold climate designationAHRI reference: 21548803619.008.60170002.00EPA 3628073
CA*EA3626*3A*+ furnace: G*VC961005CNB*Cold climate designationAHRI reference: 21548803719.008.60170002.00EPA 3628074
CHPEA3026*3A*+ furnace: G*VM970803BNB*Cold climate designationAHRI reference: 21548803919.008.60170002.00EPA 3628076
CHPEA3026*3A*+ furnace: G*VC800803B*A*Cold climate designationAHRI reference: 21548804419.008.60170002.00EPA 3628081

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

GZV7S — product specificationsManufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →