GZV7SA2410A*
GZV7SA · source records, page 4
93 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GZV7SA2410A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 93 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 93 / 93 |
| EER2 · BTU/Wh | 10.5–11 | 93 / 93 |
| HSPF2 · BTU/Wh | 8.5–8.8 | 93 / 93 |
| Cooling capacity · BTU/h | 23,200 | 93 / 93 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,200 | 93 / 93 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15,800 | 93 / 93 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000 | 93 / 93 |
| COP at 5°F / −15°C | 2 | 93 / 93 |
| Equipment / loop type | HP - Split System | 93 / 93 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 93 / 93 |
| Compressor staging | Continuously variable | 93 / 93 |
| Connected capability | No · Yes | 93 / 93 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern GZV7SA2410A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 132 lb | GZV7S — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 25 A | GZV7S — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 22.4 A | GZV7S — product specifications · page 3 ↗ |
| Shipping weight | 147 lb | GZV7S — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | GZV7S — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CA*EA3022*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 215434086 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625446 → |
CA*EA3022*3A*+ furnace: G*VT800603B*A*Cold climate designationAHRI reference: 215434087 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625447 → |
CA*EA3022*3A*+ furnace: G*VT800803B*A*Cold climate designationAHRI reference: 215434088 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625448 → |
CA*EA3022*3A*+ furnace: G*VT800804C*A*Cold climate designationAHRI reference: 215434089 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625449 → |
CA*EA3022*3A*+ furnace: G*VM970803BNB*Cold climate designationAHRI reference: 215488010 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628014 → |
CA*EA3022*3A*+ furnace: G*VC800803B*A*Cold climate designationAHRI reference: 215488014 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628018 → |
CA*EA3022*3A*+ furnace: G*VC960403BNB*Cold climate designationAHRI reference: 215488018 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628055 → |
CA*EA3022*3A*+ furnace: G*VC960603BNB*Cold climate designationAHRI reference: 215488019 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628056 → |
CA*EA3022*3A*+ furnace: G*VC960803BNB*Cold climate designationAHRI reference: 215488020 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628057 → |
CA*EA3022*3A*+ furnace: G*VC960804CNB*Cold climate designationAHRI reference: 215488021 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628058 → |
CA*EA3022*3A*+ furnace: G*VC961005CNB*Cold climate designationAHRI reference: 215488022 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628059 → |
CA*EA3626*3A*+ furnace: G*VM970803BNB*Cold climate designationAHRI reference: 215488024 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628061 → |
CA*EA3626*3A*+ furnace: G*VC800803B*A*Cold climate designationAHRI reference: 215488029 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628066 → |
CA*EA3626*3A*+ furnace: G*VC960403BNB*Cold climate designationAHRI reference: 215488033 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628070 → |
CA*EA3626*3A*+ furnace: G*VC960603BNB*Cold climate designationAHRI reference: 215488034 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628071 → |
CA*EA3626*3A*+ furnace: G*VC960803BNB*Cold climate designationAHRI reference: 215488035 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628072 → |
CA*EA3626*3A*+ furnace: G*VC960804CNB*Cold climate designationAHRI reference: 215488036 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628073 → |
CA*EA3626*3A*+ furnace: G*VC961005CNB*Cold climate designationAHRI reference: 215488037 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628074 → |
CHPEA3026*3A*+ furnace: G*VM970803BNB*Cold climate designationAHRI reference: 215488039 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628076 → |
CHPEA3026*3A*+ furnace: G*VC800803B*A*Cold climate designationAHRI reference: 215488044 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3628081 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
GZV7S — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values