Goodman / AIR-SOURCE HEAT PUMP

GZV7SA2410A*

GZV7SA

93 published source records · source checked Sep 21, 2026

SEER2 range16–19BTU/Wh
HSPF2 range8.5–8.8BTU/Wh
Cooling capacity23,200BTU/h

Each efficiency range summarizes published EPA records for GZV7SA2410A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 93 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1993 / 93
EER2 · BTU/Wh10.5–1193 / 93
HSPF2 · BTU/Wh8.5–8.893 / 93
Cooling capacity · BTU/h23,20093 / 93
Heating capacity at 47°F / 8.3°C · BTU/h23,20093 / 93
Heating capacity at 17°F / −8.3°C · BTU/h15,80093 / 93
Heating capacity at 5°F / −15°C · BTU/h17,00093 / 93
COP at 5°F / −15°C293 / 93
Equipment / loop typeHP - Split System93 / 93
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)93 / 93
Compressor stagingContinuously variable93 / 93
Connected capabilityNo · Yes93 / 93

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern GZV7SA2410A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight132 lbGZV7S — product specifications · page 3
Maximum overcurrent protection25 AGZV7S — product specifications · page 3
Minimum circuit ampacity22.4 AGZV7S — product specifications · page 3
Shipping weight147 lbGZV7S — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseGZV7S — product specifications · page 3

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
AHVE36CP1300A*Cold climate designationAHRI reference: 21542919619.008.80170002.00EPA 3625027
AHVE36CP0300A*Cold climate designationAHRI reference: 21542973419.008.80170002.00EPA 3625054
CA*EA3022*3A*+ furnace: G*VT800805C*A*Cold climate designationAHRI reference: 21543409019.008.60170002.00EPA 3625096
CA*EA3022*3A*+ furnace: G*VT801005C*A*Cold climate designationAHRI reference: 21543409119.008.60170002.00EPA 3625097
CA*EA3022*3A*+ furnace: G*VT960403BNA*Cold climate designationAHRI reference: 21543409219.008.60170002.00EPA 3625098
CA*EA3022*3A*+ furnace: G*VT960603BNA*Cold climate designationAHRI reference: 21543409319.008.60170002.00EPA 3625099
CA*EA3022*3A*+ furnace: G*VT960803BNA*Cold climate designationAHRI reference: 21543409419.008.60170002.00EPA 3625100
CA*EA3022*3A*+ furnace: G*VT960804CNA*Cold climate designationAHRI reference: 21543409519.008.60170002.00EPA 3625101
CA*EA3022*3A*+ furnace: G*VT961005CNA*Cold climate designationAHRI reference: 21543409619.008.60170002.00EPA 3625102
CA*EA3626*3A*+ furnace: G*VM970603BNA*Cold climate designationAHRI reference: 21543409719.008.60170002.00EPA 3625103
CA*EA3626*3A*+ furnace: G*VM970803BNA*Cold climate designationAHRI reference: 21543409819.008.60170002.00EPA 3625104
CA*EA3626*3A*+ furnace: G*VM970804CNA*Cold climate designationAHRI reference: 21543409919.008.60170002.00EPA 3625105
CA*EA3626*3A*+ furnace: G*VM971005CNA*Cold climate designationAHRI reference: 21543410019.008.60170002.00EPA 3625106
CA*EA3626*3A*+ furnace: G*VS800604BUA*Cold climate designationAHRI reference: 21543410119.008.60170002.00EPA 3625107
CA*EA3626*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 21543410219.008.60170002.00EPA 3625108
CA*EA3626*3A*+ furnace: G*VS960603BUA*Cold climate designationAHRI reference: 21543410319.008.60170002.00EPA 3625109
CA*EA3626*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 21543410419.008.60170002.00EPA 3625110
CA*EA3626*3A*+ furnace: G*VT800603B*A*Cold climate designationAHRI reference: 21543410519.008.60170002.00EPA 3625111
CA*EA3626*3A*+ furnace: G*VT800604B*A*Cold climate designationAHRI reference: 21543410619.008.60170002.00EPA 3625112
CA*EA3626*3A*+ furnace: G*VT800803B*A*Cold climate designationAHRI reference: 21543410719.008.60170002.00EPA 3625113

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

GZV7S — product specificationsManufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →