GZV6SA1810A*
GZV6SA · source records, page 3
73 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GZV6SA1810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 73 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 73 / 73 |
| EER2 · BTU/Wh | 11–12 | 73 / 73 |
| HSPF2 · BTU/Wh | 8.5–8.8 | 73 / 73 |
| Cooling capacity · BTU/h | 17,000–17,100 | 73 / 73 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,800–17,400 | 73 / 73 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,600–10,800 | 73 / 73 |
| Heating capacity at 5°F / −15°C · BTU/h | 12,600–13,000 | 73 / 73 |
| COP at 5°F / −15°C | 2–2.1 | 73 / 73 |
| Equipment / loop type | HP - Split System | 73 / 73 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 73 / 73 |
| Compressor staging | Continuously variable | 73 / 73 |
| Connected capability | No · Yes | 73 / 73 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern GZV6SA1810A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 122 lb | GZV6S — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 15 A | GZV6S — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 12.8 A | GZV6S — product specifications · page 3 ↗ |
| Shipping weight | 137 lb | GZV6S — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | GZV6S — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CA*EA3022*3A*+ furnace: G*VS800604BUA*Cold climate designationAHRI reference: 215439750 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3627787 → |
CA*EA2418*3A*+ furnace: G*VT800603B*A*Cold climate designationAHRI reference: 215439741 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3627788 → |
CA*EA2418*3A*+ furnace: G*VS960805CUA*Cold climate designationAHRI reference: 215439743 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3627789 → |
CHPEA2422*3A*+ furnace: G*VS960603BUA*Cold climate designationAHRI reference: 215439744 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3627790 → |
CA*EA3022*3A*+ furnace: G*VS960603BUA*Cold climate designationAHRI reference: 215439745 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3627791 → |
CA*EA2418*3A*+ furnace: G*VS960603BUA*Cold climate designationAHRI reference: 215439746 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3627792 → |
CA*EA2418*3A*+ furnace: G*VS800805CUA*Cold climate designationAHRI reference: 215439748 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3627793 → |
CHPEA2422*3A*+ furnace: G*VS800604BUA*Cold climate designationAHRI reference: 215439749 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3627794 → |
CA*EA2418*3A*+ furnace: G*VS800604BUA*Cold climate designationAHRI reference: 215439751 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3627795 → |
CA*EA3022*3A*+ furnace: G*VC960804CNB*Cold climate designationAHRI reference: 215488137 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3628276 → |
CA*EA2418*3A*+ furnace: G*VC960804CNB*Cold climate designationAHRI reference: 215488138 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3628277 → |
CHPEA2422*3A*+ furnace: G*VC960803BNB*Cold climate designationAHRI reference: 215488139 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3628278 → |
CA*EA3022*3A*+ furnace: G*VC960803BNB*Cold climate designationAHRI reference: 215488140 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3628279 → |
CA*EA2418*3A*+ furnace: G*VC960803BNB*Cold climate designationAHRI reference: 215488141 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3629049 → |
CHPEA2422*3A*+ furnace: G*VC960603BNB*Cold climate designationAHRI reference: 215488142 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3629050 → |
CA*EA3022*3A*+ furnace: G*VC960603BNB*Cold climate designationAHRI reference: 215488143 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3629051 → |
CA*EA2418*3A*+ furnace: G*VC960603BNB*Cold climate designationAHRI reference: 215488144 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3629052 → |
CHPEA2422*3A*+ furnace: G*VC960403BNB*Cold climate designationAHRI reference: 215488145 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3629053 → |
CA*EA3022*3A*+ furnace: G*VC960403BNB*Cold climate designationAHRI reference: 215488146 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3629054 → |
CA*EA2418*3A*+ furnace: G*VC960403BNB*Cold climate designationAHRI reference: 215488147 | 19.00 | 8.80 | 13000 | 2.10 | EPA 3629055 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
GZV6S — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →