GeoSmart Energy / GEOTHERMAL HEAT PUMP

GTZ049*1*J

PREMIUM G

4 published source records · source checked Sep 21, 2026

Source records4Individual ratings shown below
Equipment classGeothermal heat pump

Ground-source performance depends on the loop type and test conditions. Open-loop and closed-loop COP/EER are kept in separate source records.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Reported metrics & equipment details

Ranges include the 4 published source records for this model. Values in different rows may describe different configurations or loop types. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
Heating COP4.2–4.82 / 4
Cooling EER · BTU/Wh21.9–27.62 / 4
Equipment / loop typeClosed Loop Water-to-Air · Open Loop Water-to-Air4 / 4
RefrigerantR-410A4 / 4

Additional model ratings from NRCan

Natural Resources Canada reports the same brand, literal model and loop type in its public ground-source equipment list. These are separate source listings with their own verification references. They supplement missing EPA fields; they do not change the original EPA record or establish that different certification entries are interchangeable.

Cooling COP is dimensionless and is shown as reported. It is not labeled EER. Multiple rows retain different source verification references.

Model / loopHeating COPCooling COPCooling capacity · BTU/hHeating capacity · BTU/hNRCan verification reference
GeoSmart Energy GTZ049*1*JOpen Loop Water-to-Air4.67.0951,00047,100AHRI-207200601Checked Sep 21, 2026
GeoSmart Energy GTZ049*1*JOpen Loop Water-to-Air4.67.0951,00047,100AHRI-203490420Checked Sep 21, 2026
GeoSmart Energy GTZ049*1*JOpen Loop Water-to-Air4.67.0951,00047,100AHRI-203490411Checked Sep 21, 2026
GeoSmart Energy GTZ049*1*JOpen Loop Water-to-Air4.67.0951,00047,100AHRI-207200602Checked Sep 21, 2026
GeoSmart Energy GTZ049*1*JClosed Loop Water-to-Air3.95.2846,30037,700AHRI-207200601Checked Sep 21, 2026
GeoSmart Energy GTZ049*1*JClosed Loop Water-to-Air3.95.2846,30037,700AHRI-203490420Checked Sep 21, 2026
GeoSmart Energy GTZ049*1*JClosed Loop Water-to-Air3.95.2846,30037,700AHRI-203490411Checked Sep 21, 2026
GeoSmart Energy GTZ049*1*JClosed Loop Water-to-Air3.95.2846,30037,700AHRI-207200602Checked Sep 21, 2026

Source: NRCan searchable product list → Download all (CSV). Match the brand, model number and reference above. Canadian programme eligibility is not a claim about US incentives or certification.

Published source records

Each row retains its own equipment and test conditions. Open the record for all specifications.

Loop / equipment typeHeating COPCooling EERBTU/WhRecord & comparison
Open Loop Water-to-AirEPA 2383370
Closed Loop Water-to-AirEPA 2383372
Closed Loop Water-to-Air4.221.9EPA 3845593
Open Loop Water-to-Air4.827.6EPA 3845887

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →