NS22H60MA4-**A
NS22 Series · NS22H SERIES · NS22H Series
17 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS22H60MA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 17 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–19 | 17 / 17 |
| EER2 · BTU/Wh | 11.7–12 | 17 / 17 |
| HSPF2 · BTU/Wh | 7.8–8.7 | 17 / 17 |
| Cooling capacity · BTU/h | 54,000–55,000 | 17 / 17 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 55,000–56,000 | 17 / 17 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,000–38,000 | 17 / 17 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,200 | 17 / 17 |
| COP at 5°F / −15°C | 1.84–2.12 | 17 / 17 |
| Equipment / loop type | HP - Split System | 17 / 17 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 17 / 17 |
| Compressor staging | Continuously variable | 17 / 17 |
| Connected capability | No | 17 / 17 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NAM60V2TA4AHRI reference: 212403760 | 19.00 | 8.70 | 29800 | 2.12 | EPA 2471857 → |
NCUC5060CT4+TDR+ furnace: NF97U110V5CAHRI reference: 215283908 | 19.00 | 8.00 | 30400 | 1.86 | EPA 3619394 → |
NCUC50CT5D-**+TDR+ furnace: NF97U110V5CAHRI reference: 215283912 | 19.00 | 8.00 | 30400 | 1.86 | EPA 3619395 → |
NCUC5060CT4+TDR+ furnace: NF98U110M5CAHRI reference: 215438331 | 19.00 | 7.80 | 30600 | 1.84 | EPA 3627595 → |
NCUC50/60CT4+ furnace: NF97U110M5CAHRI reference: 212403777 | 18.00 | 8.00 | 30600 | 1.84 | EPA 2471968 → |
NCUC60CT5D-**+TDR+ furnace: NF97U110V5CAHRI reference: 215283920 | 18.00 | 8.20 | 31200 | 2.02 | EPA 3619396 → |
NCUC60DT4+TDR+ furnace: NF97U135V5DAHRI reference: 215283922 | 18.00 | 8.10 | 30800 | 1.98 | EPA 3619397 → |
NCUC60DT5D-**+TDR+ furnace: NF97U135V5DAHRI reference: 215283925 | 18.00 | 8.10 | 30800 | 1.98 | EPA 3619398 → |
NCUU60CP4+TDR+TXV+ furnace: NF97U110V5CAHRI reference: 215283929 | 18.00 | 8.20 | 31200 | 2.02 | EPA 3619399 → |
NCUC60CT4+TDR+ furnace: NF97U110V5CAHRI reference: 215283916 | 18.00 | 8.20 | 31200 | 2.02 | EPA 3619438 → |
NCUC60CT4+TDR+ furnace: NF98U110M5CAHRI reference: 215438334 | 18.00 | 8.20 | 31200 | 2.02 | EPA 3627596 → |
NCUC60DT4+TDR+ furnace: NF98U135M5DAHRI reference: 215438335 | 18.00 | 8.10 | 30800 | 1.96 | EPA 3627597 → |
NCUU60CP4+TDR+TXV+ furnace: NF98U110M5CAHRI reference: 215438338 | 18.00 | 8.20 | 31200 | 2.02 | EPA 3627598 → |
NCUC60DT4+TDR+ furnace: NF97U135M5DAHRI reference: 212403788 | 17.00 | 8.20 | 30800 | 1.98 | EPA 2471461 → |
NCUC60DT4+TDR+ furnace: NF96U135V5DAHRI reference: 212403787 | 17.00 | 8.20 | 30800 | 1.98 | EPA 2471751 → |
NCUC60CT4+TDR+ furnace: NF97U110M5CAHRI reference: 212403785 | 17.00 | 8.50 | 31200 | 2.02 | EPA 3801667 → |
NCUU60CP4+TDR+TXV+ furnace: NF97U110M5CAHRI reference: 212403795 | 17.00 | 8.50 | 31200 | 2.02 | EPA 3801669 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →