NS22H48MA4-**A
NS22H Series
28 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS22H48MA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 28 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18.5–19.5 | 28 / 28 |
| EER2 · BTU/Wh | 11.7–12 | 28 / 28 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 28 / 28 |
| Cooling capacity · BTU/h | 45,000–47,500 | 28 / 28 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–45,500 | 28 / 28 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,200–28,800 | 28 / 28 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,600–25,200 | 28 / 28 |
| COP at 5°F / −15°C | 1.82–2.04 | 28 / 28 |
| Equipment / loop type | HP - Split System | 28 / 28 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 28 / 28 |
| Compressor staging | Continuously variable | 28 / 28 |
| Connected capability | No | 28 / 28 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NAM60V2TA4AHRI reference: 212403797 | 19.50 | 8.50 | 23200 | 2.02 | EPA 3477483 → |
NCHC48CT4+TDR+ furnace: NF97U110M5CAHRI reference: 212403807 | 19.00 | 7.80 | 24000 | 1.84 | EPA 2471415 → |
NCHC51CT4+TDR+ furnace: NF97U110M5CAHRI reference: 212403816 | 19.00 | 7.80 | 24400 | 1.88 | EPA 2471425 → |
NCHC48CT4+TDR+ furnace: NF96U110V5CAHRI reference: 212403804 | 19.00 | 7.80 | 24000 | 1.82 | EPA 2471456 → |
NAM48V2TA4AHRI reference: 212403799 | 19.00 | 8.00 | 22600 | 1.90 | EPA 2471465 → |
NCHC51CT4+TDR+ furnace: NF97U090M5CAHRI reference: 212403815 | 19.00 | 7.80 | 24400 | 1.86 | EPA 2471565 → |
NCUU60CP4+TDR+TXV+ furnace: NF97U110M5CAHRI reference: 212403833 | 19.00 | 8.50 | 24800 | 2.04 | EPA 2471853 → |
NCUC60CT4+TDR+ furnace: NF97U110M5CAHRI reference: 212403825 | 19.00 | 8.50 | 24800 | 2.04 | EPA 2471960 → |
NCHC51CT4+TDR+ furnace: NF96U110V5CAHRI reference: 212403813 | 19.00 | 7.80 | 24400 | 1.88 | EPA 2472084 → |
NCUU60CP4+TDR+TXV+ furnace: NF97X080V5CAHRI reference: 212403835 | 18.50 | 8.20 | 25000 | 2.02 | EPA 2471373 → |
NCUC60CT4+TDR+ furnace: NF97X080V4CAHRI reference: 212403826 | 18.50 | 8.20 | 25000 | 2.02 | EPA 2471402 → |
NCUC60CT4+TDR+ furnace: NF96U090V5CAHRI reference: 212403821 | 18.50 | 8.20 | 25000 | 2.02 | EPA 2471403 → |
NCUC60CT4+TDR+ furnace: NF97X080V5CAHRI reference: 212403827 | 18.50 | 8.20 | 25000 | 2.02 | EPA 2471409 → |
NCHC51CT4+TDR+ furnace: NF97X080V5CAHRI reference: 212403818 | 18.50 | 7.80 | 24400 | 1.86 | EPA 2471417 → |
NCUC60CT4+TDR+ furnace: NF97U090M4CAHRI reference: 212403823 | 18.50 | 8.20 | 25200 | 2.02 | EPA 2471431 → |
NCUU60CP4+TDR+TXV+ furnace: NF96U110V5CAHRI reference: 212403830 | 18.50 | 8.50 | 25000 | 2.04 | EPA 2471459 → |
NCHC51CT4+TDR+ furnace: NF97X080V4CAHRI reference: 212403817 | 18.50 | 7.80 | 24400 | 1.86 | EPA 2471460 → |
NCUU60CP4+TDR+TXV+ furnace: NF97X080V4CAHRI reference: 212403834 | 18.50 | 8.20 | 25000 | 2.02 | EPA 2471539 → |
NCHC48CT4+TDR+ furnace: NF97U090M5CAHRI reference: 212403806 | 18.50 | 7.80 | 24000 | 1.82 | EPA 2471649 → |
NCUU60CP4+TDR+TXV+ furnace: NF97U090M4CAHRI reference: 212403831 | 18.50 | 8.20 | 25200 | 2.02 | EPA 2471661 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →