GE / AIR-SOURCE HEAT PUMP

NS22H36MA4-**A

NS22H SERIES · source records, page 4

73 published source records · source checked Sep 21, 2026

SEER2 range17.5–20.5BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity34,000–36,000BTU/h

Each efficiency range summarizes published EPA records for NS22H36MA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 73 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.5–20.573 / 73
EER2 · BTU/Wh11.7–1273 / 73
HSPF2 · BTU/Wh8.5–973 / 73
Cooling capacity · BTU/h34,000–36,00073 / 73
Heating capacity at 47°F / 8.3°C · BTU/h32,800–35,00073 / 73
Heating capacity at 17°F / −8.3°C · BTU/h21,800–23,00073 / 73
Heating capacity at 5°F / −15°C · BTU/h17,800–18,60073 / 73
COP at 5°F / −15°C2.02–2.373 / 73
Equipment / loop typeHP - Split System73 / 73
Refrigerant / source-reported GWPR-410A (GWP:2088)73 / 73
Compressor stagingContinuously variable73 / 73
Connected capabilityNo73 / 73

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUU30BP4+TDR+TXV+ furnace: NF97X060V3BAHRI reference: 21240391319.508.50180002.10EPA 2472499 →
NCUU48BP4+TDR+TXV+ furnace: NF97X060V3BAHRI reference: 21240392819.508.80185002.18EPA 2472572 →
NCUC30BT4+TDR+ furnace: NF96U045V3BAHRI reference: 21240387519.008.50181002.10EPA 2471213 →
NCHC42CT4+TDR+ furnace: NF97U090M3CAHRI reference: 21240386619.008.70181002.16EPA 2471218 →
NCHC42CT4+TDR+ furnace: NF97U090M5CAHRI reference: 21240386819.008.70182002.16EPA 2471517 →
NCUU48BP4+TDR+TXV+ furnace: NF96U045V3BAHRI reference: 21240392419.008.70186002.16EPA 2471696 →
NCUU30BP4+TDR+TXV+ furnace: NF96U045V3BAHRI reference: 21240390919.008.50181002.10EPA 2471724 →
NCHC42CT4+TDR+ furnace: NF96U090V5CAHRI reference: 21240386419.008.70181002.16EPA 2471928 →
NCHC30BT4+TDR+ furnace: NF97X040V3BAHRI reference: 21240384819.008.50186002.10EPA 2472163 →
NCUC48BT4+TDR+ furnace: NF96U045V3BAHRI reference: 21240389019.008.70186002.16EPA 2472178 →
NCHC42CT4+TDR+ furnace: NF97X080V4CAHRI reference: 21240387019.008.70183002.18EPA 2472463 →
NAM42E1ATAHRI reference: 21240384018.508.80181002.22EPA 2471237 →
NAM36E1ATAHRI reference: 21240383917.508.80178002.18EPA 2472257 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →