GE / AIR-SOURCE HEAT PUMP

NS21H36MA5-**A

NS21H SERIES · NS21H Series

133 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range8.5–10.4BTU/Wh
Cooling capacity32,000–34,800BTU/h

Each efficiency range summarizes published EPA records for NS21H36MA5-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 133 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20133 / 133
EER2 · BTU/Wh11–12.2133 / 133
HSPF2 · BTU/Wh8.5–10.4133 / 133
Cooling capacity · BTU/h32,000–34,800133 / 133
Heating capacity at 47°F / 8.3°C · BTU/h30,000–34,600133 / 133
Heating capacity at 17°F / −8.3°C · BTU/h26,600–31,400133 / 133
Heating capacity at 5°F / −15°C · BTU/h18,400–24,400133 / 133
COP at 5°F / −15°C1.9–2.46133 / 133
Equipment / loop typeHP - Split System133 / 133
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)133 / 133
Compressor stagingContinuously variable133 / 133
Connected capabilityNo133 / 133

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NAM42V1TA5*-**Cold climate designationAHRI reference: 21764252820.009.00238002.08EPA 4481675 →
NCDC36BT5*-**+TDR+ furnace: NF97D070M3B*AHRI reference: 21764266019.509.20192002.36EPA 4481544 →
NAM42E1TA5*-**Cold climate designationAHRI reference: 21764256119.508.50244002.06EPA 4481755 →
NAM36V1TA5*-**Cold climate designationAHRI reference: 21764256319.508.50242002.06EPA 4481756 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21764265019.0010.40230002.26EPA 4481534 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF97X040V3B*AHRI reference: 21764265119.0010.40232002.24EPA 4481535 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF98U070M3B*AHRI reference: 21764265319.0010.40228002.28EPA 4481537 →
NCDC36CT5*-**+TDR+ furnace: NF97D090M4C*AHRI reference: 21764267619.009.20195002.28EPA 4481564 →
NCHC30BT5*-**+TDR+ furnace: NF97X040V3B*Cold climate designationAHRI reference: 21764268219.009.00232002.38EPA 4481569 →
NCHC30BT5*-**+TDR+ furnace: NF98U070M3B*Cold climate designationAHRI reference: 21764268419.009.40228002.44EPA 4481571 →
NCU[C,U]30AT5*-**+TDR+ furnace: NF80X060S3A*AHRI reference: 21764263219.0010.40226002.26EPA 4481720 →
NCU[C,U]30AT5*-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21764263419.0010.40224002.26EPA 4481722 →
NCU[C,U]30AT5*-**+TDR+ furnace: NF80L045S3A*AHRI reference: 21764263619.0010.40224002.26EPA 4481723 →
NCU[C,U]30AT5*-**+TDR+ furnace: NF80X040S3A*AHRI reference: 21764271719.0010.40226002.26EPA 4481792 →
NCU[C,U]30AT5*-**+TDR+ furnace: NF80U045S3A*AHRI reference: 21764263519.0010.40224002.26EPA 4481803 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21764264418.5010.40226002.28EPA 4481529 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21764265218.5010.40232002.24EPA 4481536 →
NCHC30AT5*-**+TDR+ furnace: NF80U045T3A*Cold climate designationAHRI reference: 21764266518.509.00242001.96EPA 4481549 →
NCHC30BT5*-**+TDR+ furnace: NF80X080V4B*Cold climate designationAHRI reference: 21764268118.509.00228002.42EPA 4481568 →
NCHC30BT5*-**+TDR+ furnace: NF97X060V3B*Cold climate designationAHRI reference: 21764268318.509.00232002.40EPA 4481570 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →