GE / AIR-SOURCE HEAT PUMP

NS21H24MA5-**A

NS21H SERIES · NS21H Series · source records, page 3

91 published source records · source checked Sep 21, 2026

SEER2 range15.2–20.5BTU/Wh
HSPF2 range8.2–10.2BTU/Wh
Cooling capacity21,600–24,000BTU/h

Each efficiency range summarizes published EPA records for NS21H24MA5-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 91 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20.591 / 91
EER2 · BTU/Wh11.2–13.491 / 91
HSPF2 · BTU/Wh8.2–10.291 / 91
Cooling capacity · BTU/h21,600–24,00091 / 91
Heating capacity at 47°F / 8.3°C · BTU/h24,000–27,40091 / 91
Heating capacity at 17°F / −8.3°C · BTU/h18,800–22,40091 / 91
Heating capacity at 5°F / −15°C · BTU/h13,900–18,60091 / 91
COP at 5°F / −15°C1.7–2.391 / 91
Equipment / loop typeHP - Split System91 / 91
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)91 / 91
Compressor stagingContinuously variable91 / 91
Connected capabilityNo91 / 91

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCU[C,U]24AT5*-**+TDR+ furnace: NF80X060S3A*AHRI reference: 21764256619.008.50142001.74EPA 4481759 →
NCU[C,U]24AT5*-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21764256819.008.50143001.74EPA 4481761 →
NCU[C,U]24BT5*-**+TDR+ furnace: NF97U045V3B*AHRI reference: 21764257619.008.20140001.74EPA 4481769 →
NCU[C,U]24BT5*-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21764257919.008.50143001.74EPA 4481771 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF80L070S3B*Cold climate designationAHRI reference: 21764251719.009.80174002.10EPA 4481814 →
NCU[C,U]24BT5*-**+TDR+ furnace: NF80U090V4B*AHRI reference: 21790178819.008.20141001.74EPA 4573338 →
NCHC30AT5*-**+TDR+ furnace: NF80U070V3A*AHRI reference: 21790179519.009.00170002.06EPA 4573341 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF97U070T3B*Cold climate designationAHRI reference: 21815975919.009.80178002.10EPA 4577850 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF95X040S3B*Cold climate designationAHRI reference: 21764250918.509.80178002.08EPA 4481657 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF95X060S3B*Cold climate designationAHRI reference: 21764251018.509.80178002.08EPA 4481658 →
NCU[C,U]30BT5*-**+TDR+ furnace: NF96U045S3B*Cold climate designationAHRI reference: 21764251818.509.80178002.08EPA 4481665 →
NCDC36BT5*-**+TDR+ furnace: NF96D045S3B*AHRI reference: 21764260418.508.50163002.02EPA 4481693 →
NCHC30BT5*-**+TDR+ furnace: NF95X040S3B*Cold climate designationAHRI reference: 21764260718.509.00172002.04EPA 4481696 →
NCHC30BT5*-**+TDR+ furnace: NF95X060S3B*Cold climate designationAHRI reference: 21764260818.509.00172002.04EPA 4481697 →
NCDC36CT5*-**+TDR+ furnace: NF97D110M5C*AHRI reference: 21764261118.508.50163002.02EPA 4481699 →
NCHC30BT5*-**+TDR+ furnace: NF96U045S3B*Cold climate designationAHRI reference: 21764261518.509.00173002.04EPA 4481703 →
NCHC30BT5*-**+TDR+ furnace: NF96U070S3B*Cold climate designationAHRI reference: 21764261618.509.00171002.06EPA 4481704 →
NCHC30AT5*-**+TDR+ furnace: NF80X040S3A*AHRI reference: 21764262518.509.00171002.06EPA 4481713 →
NCHC30AT5*-**+TDR+ furnace: NF80X060S3A*AHRI reference: 21764262618.509.00171002.06EPA 4481714 →
NCHC30AT5*-**+TDR+ furnace: NF80L070S3A*AHRI reference: 21764263018.509.00168002.04EPA 4481718 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.