GE / AIR-SOURCE HEAT PUMP

NS19H36MA5-**A

NS19H SERIES · NS19H Series · source records, page 8

152 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,800BTU/h

Each efficiency range summarizes published EPA records for NS19H36MA5-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 152 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20152 / 152
EER2 · BTU/Wh11–13.2152 / 152
HSPF2 · BTU/Wh7.8–8.5152 / 152
Cooling capacity · BTU/h21,600–35,800152 / 152
Heating capacity at 47°F / 8.3°C · BTU/h22,800–35,400152 / 152
Heating capacity at 17°F / −8.3°C · BTU/h14,200–21,600152 / 152
Heating capacity at 5°F / −15°C · BTU/h13,700–17,700152 / 152
COP at 5°F / −15°C1.48–2.2152 / 152
Equipment / loop typeHP - Split System152 / 152
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)152 / 152
Compressor stagingContinuously variable152 / 152
Connected capabilityNo152 / 152

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCU[C,U]37CT5*-**+TDR+ furnace: NF80X100S5C*AHRI reference: 21837441516.008.20150001.92EPA 4591098
NCU[C,U]37CT5*-**+TDR+ furnace: NF97U110T5C*AHRI reference: 21875019216.008.20151001.92EPA 4705736
NCU[C,U]24BT5*-**+TDRAHRI reference: 21773315015.508.50170001.98EPA 4512900
NCU[C,U]24AT5*-**+TDRAHRI reference: 21773316415.508.50170001.98EPA 4512912
NCHC36CT5*-**+TDR+ furnace: NF80X100S5C*AHRI reference: 21773299715.508.10165002.06EPA 4512961
NCDC36BT5*-**+TDR+ furnace: NF80D090T4B*AHRI reference: 21773312415.508.00164002.10EPA 4512999
NCDC36BT5*-**+TDR+ furnace: NF80D090S4B*AHRI reference: 21773312515.508.00163002.10EPA 4513000
NCDC36CT5*-**+TDR+ furnace: NF80D110S5C*AHRI reference: 21773312615.508.00165002.12EPA 4513001
NCDC36CT5*-**+TDR+ furnace: NF96D090S4C*AHRI reference: 21773312715.508.00163002.12EPA 4513002
NAM30P1TA5*-**AHRI reference: 21773321515.508.20162001.84EPA 4513038
NCU[C,U]37CT5*-**+TDR+ furnace: NF96U110S5C*AHRI reference: 21837441915.508.20151001.92EPA 4591094
NCHC30BT5*-**+TDRAHRI reference: 21773315115.208.10157001.84EPA 4512901

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →