GE / AIR-SOURCE HEAT PUMP

NS19H36MA5-**A

NS19H SERIES · NS19H Series · source records, page 2

152 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,800BTU/h

Each efficiency range summarizes published EPA records for NS19H36MA5-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 152 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20152 / 152
EER2 · BTU/Wh11–13.2152 / 152
HSPF2 · BTU/Wh7.8–8.5152 / 152
Cooling capacity · BTU/h21,600–35,800152 / 152
Heating capacity at 47°F / 8.3°C · BTU/h22,800–35,400152 / 152
Heating capacity at 17°F / −8.3°C · BTU/h14,200–21,600152 / 152
Heating capacity at 5°F / −15°C · BTU/h13,700–17,700152 / 152
COP at 5°F / −15°C1.48–2.2152 / 152
Equipment / loop typeHP - Split System152 / 152
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)152 / 152
Compressor stagingContinuously variable152 / 152
Connected capabilityNo152 / 152

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCU[C,U]24BT5*-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21773316019.008.50164002.02EPA 4512909
NCU[C,U]24BT5*-**+TDR+ furnace: NF98U070M3B*AHRI reference: 21773316119.008.50163002.02EPA 4512910
NCU[C,U]24BT5*-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21773316319.008.50166002.02EPA 4512911
NCU[C,U]24AT5*-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21773316819.008.50166002.02EPA 4512916
NCU[C,U]24AT5*-**+TDR+ furnace: NF80U045S3A*AHRI reference: 21773316919.008.50162002.00EPA 4512917
NCU[C,U]24AT5*-**+TDR+ furnace: NF80L045S3A*AHRI reference: 21773317019.008.50162002.00EPA 4512918
NCU[C,U]24AT5*-**+TDR+ furnace: NF80X060V3A*AHRI reference: 21773317319.008.50164002.02EPA 4512921
NCU[C,U]30BT5*-**+TDR+ furnace: NF97U045V3B*AHRI reference: 21773318319.008.10138001.88EPA 4512930
NCU[C,U]30BT5*-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21773318519.008.10139001.86EPA 4512932
NCU[C,U]36BT5*-**+TDR+ furnace: NF97X040V3B*AHRI reference: 21773294519.008.50152001.88EPA 4512937
NCU[C,U]36BT5*-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21773294619.008.50152001.88EPA 4512938
NCU[C,U]36BT5*-**+TDR+ furnace: NF98U070M3B*AHRI reference: 21773294719.008.50151001.88EPA 4512939
NCU[C,U]36AT5*-**+TDR+ furnace: NF80X060V3A*AHRI reference: 21773294919.008.50151001.88EPA 4512941
NAM24V1TA5*-**AHRI reference: 21773295019.008.20156001.76EPA 4512942
NCU[C,U]36AT5*-**+TDR+ furnace: NF80U045T3A*AHRI reference: 21773296519.008.20151001.90EPA 4512954
NCU[C,U]30BT5*-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21773318819.008.10139001.86EPA 4513011
NCU[C,U]30BT5*-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21773319119.008.20141001.88EPA 4513014
NCU[C,U]30AT5*-**+TDR+ furnace: NF80X040S3A*AHRI reference: 21773320019.008.20140001.88EPA 4513023
NCU[C,U]30AT5*-**+TDR+ furnace: NF80X060S3A*AHRI reference: 21773320119.008.20140001.88EPA 4513024
NCU[C,U]30AT5*-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21773320319.008.20141001.88EPA 4513026

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →