GE / AIR-SOURCE HEAT PUMP

NS17H48SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 7

139 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for NS17H48SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6139 / 139
EER2 · BTU/Wh12.5–13139 / 139
HSPF2 · BTU/Wh8–8.5139 / 139
Cooling capacity · BTU/h46,000–48,000139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,800139 / 139
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600139 / 139
COP at 5°F / −15°C2.18–2.38139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-410A (GWP:2088)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC48CT5D-**+TDR+ furnace: NF96U090V3C*AHRI reference: 21749133015.208.00244002.18EPA 4433158 →
NCUC49CT5D-**+TDR+ furnace: NF96U090V3C*AHRI reference: 21749133115.208.10250002.22EPA 4433159 →
NCUC60CT5D-**+TDR+ furnace: NF96U090V3C*AHRI reference: 21749133215.208.10252002.36EPA 4433160 →
NCUC49CT5D-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21749111615.208.10256002.26EPA 4433175 →
NCHC51CT5D-**+TDR+ furnace: NF97U090V3C*AHRI reference: 21749143015.208.10254002.28EPA 4433184 →
NCUC48CT5D-**+TDR+ furnace: NF97U090V3C*AHRI reference: 21749143115.208.00244002.18EPA 4433185 →
NCHC48CT5D-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21749112615.208.00246002.18EPA 4433279 →
NCUC48BT5D-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21749106815.208.10242002.18EPA 4433293 →
NCHC51CT5D-**+TDR+ furnace: NF97U090M3C*AHRI reference: 21749141215.208.10254002.28EPA 4433305 →
NCUC48CT5D-**+TDR+ furnace: NF97U090M3C*AHRI reference: 21749141315.208.00244002.18EPA 4433306 →
NCUC49CT5D-**+TDR+ furnace: NF97U090M3C*AHRI reference: 21749141415.208.10250002.22EPA 4433307 →
NCUC60CT5D-**+TDR+ furnace: NF97U090M3C*AHRI reference: 21749141515.208.10252002.36EPA 4433308 →
NCUC49CT5D-**+TDR+ furnace: NF97U090V3C*AHRI reference: 21749143215.208.10250002.22EPA 4433317 →
NCUC60CT5D-**+TDR+ furnace: NF97U090V3C*AHRI reference: 21749143315.208.10252002.36EPA 4433318 →
NCHC60DT5D-**+TDR+ furnace: NF97U135M5D*AHRI reference: 21749144615.208.10246002.20EPA 4433330 →
NCHC60DT5D-**+TDR+ furnace: NF97U135V5D*AHRI reference: 21749144715.208.10246002.18EPA 4433331 →
NCUC60CT5D-**+TDR+ furnace: NF97X080V4C*AHRI reference: 21749148115.208.30256002.34EPA 4433348 →
NCUC60CT5D-**+TDR+ furnace: NF97X080V5C*AHRI reference: 21749148615.208.10256002.34EPA 4433353 →
NCHC51CT5D-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21749111515.208.30256002.30EPA 4433377 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →