GE / AIR-SOURCE HEAT PUMP

NS17H48SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 4

139 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for NS17H48SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6139 / 139
EER2 · BTU/Wh12.5–13139 / 139
HSPF2 · BTU/Wh8–8.5139 / 139
Cooling capacity · BTU/h46,000–48,000139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,800139 / 139
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600139 / 139
COP at 5°F / −15°C2.18–2.38139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-410A (GWP:2088)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC51CT4+TDR+ furnace: NF80U110S5C-*AHRI reference: 21026255715.208.30256002.30EPA 2459762
NCUC48CT4+TDR+ furnace: NF97U090M3C-*AHRI reference: 21026259315.208.00244002.18EPA 2460032
NCHC48CT4+TDR+ furnace: NF96U110S5C-*AHRI reference: 21026254115.208.00248002.18EPA 2460310
NCUC60CT4+TDR+ furnace: NF97X080V4C-*AHRI reference: 21026264415.208.30256002.34EPA 2460314
NCUU49CP4+TDR+TXV+ furnace: NF80U110S5C-*AHRI reference: 21026249915.208.10256002.26EPA 2461103
NCUC50/60CT4+TDR+ furnace: NF80U090S5C-*AHRI reference: 21026262115.208.00242002.18EPA 2461323
NCUU48CP4+TDR+TXV+ furnace: NF96U110S5C-*AHRI reference: 21026248315.208.10242002.18EPA 2461332
NCUU49CP4+TDR+TXV+ furnace: NF96U090S4C-*AHRI reference: 21026250015.208.10254002.24EPA 2461340
NCUU60CP4+TDR+TXV+ furnace: NF97U090M3C-*AHRI reference: 21026252415.208.10252002.36EPA 2461341
NCUC49CT4+TDR+ furnace: NF80U110S5C-*AHRI reference: 21026260415.208.10256002.26EPA 2461784
NCUC49CT4+TDR+ furnace: NF97U090M3C-*AHRI reference: 21026261115.208.10250002.22EPA 2461797
NCHC48CT4+TDR+ furnace: NF80U110T5C-*AHRI reference: 21026253515.208.00246002.18EPA 2461801
NCHC51CT4+TDR+ furnace: NF97U090M3C-*AHRI reference: 21026256315.208.10254002.28EPA 2461833
NCUU48BP4+TDR+TXV+ furnace: NF80U090S4B-*AHRI reference: 21026246815.208.10242002.18EPA 2461837
NCUU60CP4+TDR+TXV+ furnace: NF97X080V4C-*AHRI reference: 21026252215.208.30256002.34EPA 2461839
NCUU49CP4+TDR+TXV+ furnace: NF97U090M3C-*AHRI reference: 21026250615.208.10250002.22EPA 2461843
NCUC49CT4+TDR+ furnace: NF96U110S5C-*AHRI reference: 21026260615.208.10254002.26EPA 2461848
NCUC60CT4+TDR+ furnace: NF95X100S5C-*AHRI reference: 21026263315.208.10254002.38EPA 2461851
NCHC60DT4+TDR+ furnace: NF97U135M5D-*AHRI reference: 21026256915.208.10246002.20EPA 2462004
NCUC48CT4+TDR+ furnace: NF96U110S5C-*AHRI reference: 21026258815.208.10242002.18EPA 2462014

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →