GE / AIR-SOURCE HEAT PUMP

NS17H48SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 2

139 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for NS17H48SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6139 / 139
EER2 · BTU/Wh12.5–13139 / 139
HSPF2 · BTU/Wh8–8.5139 / 139
Cooling capacity · BTU/h46,000–48,000139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,800139 / 139
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600139 / 139
COP at 5°F / −15°C2.18–2.38139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-410A (GWP:2088)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC60CT4+TDR+ furnace: NF96U110S5C-*AHRI reference: 21026264115.408.10252002.34EPA 2457560
NCUU48CP4+TDR+TXV+ furnace: NF80U090S5C-*AHRI reference: 21026248015.408.10244002.22EPA 2459826
NCHC51CT4+TDR+ furnace: NF96U110S5C-*AHRI reference: 21026255815.408.30254002.28EPA 2459977
NCHC51CT4+TDR+ furnace: NF80U110T5C-*AHRI reference: 21026255215.408.30254002.28EPA 2460801
NCUC60CT4+TDR+ furnace: NF80U110S5C-*AHRI reference: 21026263915.408.30254002.34EPA 2461066
NCUC48CT4+TDR+ furnace: NF80X100V5C-*AHRI reference: 21026258915.408.10244002.20EPA 2461074
NCUC49CT4+TDR+ furnace: NF80X100V5C-*AHRI reference: 21026260715.408.10254002.26EPA 2461084
NCUC60CT4+TDR+ furnace: NF80U110V5C-*AHRI reference: 21026264315.408.30254002.32EPA 2461106
NCUC48CT4+TDR+ furnace: NF80U090S5C-*AHRI reference: 21026258515.408.10244002.22EPA 2461326
NCUU49CP4+TDR+TXV+ furnace: NF80X100V5C-*AHRI reference: 21026250215.408.10254002.26EPA 2461345
NCHC51CT4+TDR+ furnace: NF80X100V5C-*AHRI reference: 21026255915.408.30256002.30EPA 2461568
NCUU49CP4+TDR+TXV+ furnace: NF80U110T5C-*AHRI reference: 21026249415.408.10254002.26EPA 2461822
NCUU60CP4+TDR+TXV+ furnace: NF80U110V5C-*AHRI reference: 21026252115.408.30254002.32EPA 2461845
NCUU48CP4+TDR+TXV+ furnace: NF80X100V5C-*AHRI reference: 21026248415.408.10244002.20EPA 2462016
NCUU60CP4+TDR+TXV+ furnace: NF96U110S5C-*AHRI reference: 21026251915.408.10252002.34EPA 2462087
NCUC60CT4+TDR+ furnace: NF96U090S4C-*AHRI reference: 21026264015.408.10254002.36EPA 2462103
NCHC51CT5D-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21749121015.408.30256002.30EPA 4431926
NCUC48CT5D-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21749121115.408.10244002.20EPA 4431927
NCUC49CT5D-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21749121215.408.10254002.26EPA 4431928
NCUC60CT5D-**+TDR+ furnace: NF80U110V5C*AHRI reference: 21749113815.408.30254002.32EPA 4431964