GE / AIR-SOURCE HEAT PUMP

NS17H42SA4-**A

NS17H · NS17H Series

52 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range7.8–8.3BTU/Wh
Cooling capacity40,500–42,000BTU/h

Each efficiency range summarizes published EPA records for NS17H42SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 52 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.652 / 52
EER2 · BTU/Wh12.5–1352 / 52
HSPF2 · BTU/Wh7.8–8.352 / 52
Cooling capacity · BTU/h40,500–42,00052 / 52
Heating capacity at 47°F / 8.3°C · BTU/h37,600–42,00052 / 52
Heating capacity at 17°F / −8.3°C · BTU/h25,000–27,60052 / 52
Heating capacity at 5°F / −15°C · BTU/h19,600–21,80052 / 52
COP at 5°F / −15°C2–2.252 / 52
Equipment / loop typeHP - Split System52 / 52
Refrigerant / source-reported GWPR-410A (GWP:2088)52 / 52
Compressor stagingSingle stage52 / 52
Connected capabilityNo52 / 52

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUU49CP4+TDR+TXV+ furnace: NF80X100V5C-*AHRI reference: 21026245315.607.80199002.10EPA 2455020 →
NCUC49CT4+TDR+ furnace: NF80X100V5C-*AHRI reference: 21026246315.607.80199002.10EPA 2455047 →
NAM42V2TA4AHRI reference: 21067785915.608.30206002.20EPA 2458876 →
NCDC48CT4+TDR+ furnace: NF80D110S5C-*AHRI reference: 21335584515.608.30218002.12EPA 2841286 →
NCUC49CT5D-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21749120915.607.80199002.10EPA 4431925 →
NCHC42BT5D-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21749109315.607.80199002.12EPA 4432973 →
NCDC48CT5D-**+TDR+ furnace: NF80D110S5C*AHRI reference: 21749093215.608.30218002.12EPA 4432992 →
NCUC48CT5D-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21749120815.607.80197002.12EPA 4433037 →
NCUC48CT5D-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21749112415.607.80196002.12EPA 4433128 →
NCUU49CP4+TDR+TXV+ furnace: NF80U110S5C-*AHRI reference: 21026245015.407.80198002.10EPA 2454980 →
NCUC49CT4+TDR+ furnace: NF80U110T5C-*AHRI reference: 21026245815.407.80199002.08EPA 2454989 →
NCUC49CT4+TDR+ furnace: NF80U110S5C-*AHRI reference: 21026246015.407.80198002.10EPA 2455070 →
NAM42V1TA4AHRI reference: 21072048115.408.10202002.14EPA 2456499 →
NCHC48CT4+TDR+ furnace: NF80X100V5C-*AHRI reference: 21026245715.407.80202002.04EPA 2459831 →
NCUU49CP4+TDR+TXV+ furnace: NF80U090S5C-*AHRI reference: 21026244915.407.80198002.12EPA 2461104 →
NCUC49CT4+TDR+ furnace: NF80U090S5C-*AHRI reference: 21026245915.407.80198002.12EPA 2461762 →
NCUU49CP4+TDR+TXV+ furnace: NF80U110T5C-*AHRI reference: 21026244815.407.80199002.08EPA 2462099 →
NCHC42BT5D-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21749097715.407.80200002.12EPA 4431970 →
NCHC42BT5D-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21749103315.407.80202002.12EPA 4432009 →
NCUC49CT5D-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21749107515.407.80198002.12EPA 4432031 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →