GE / AIR-SOURCE HEAT PUMP

NS17H36SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 9

324 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,200–36,000BTU/h

Each efficiency range summarizes published EPA records for NS17H36SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 324 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8324 / 324
EER2 · BTU/Wh12.2–14324 / 324
HSPF2 · BTU/Wh7.8–8.7324 / 324
Cooling capacity · BTU/h35,200–36,000324 / 324
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000324 / 324
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000324 / 324
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300324 / 324
COP at 5°F / −15°C2.08–2.34324 / 324
Equipment / loop typeHP - Split System324 / 324
Refrigerant / source-reported GWPR-410A (GWP:2088)324 / 324
Compressor stagingSingle stage324 / 324
Connected capabilityNo324 / 324

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC5060CT4+TDR+ furnace: NF98U090M4CAHRI reference: 21543820816.007.80174002.12EPA 3627558
NCUC5060CT4+TDR+ furnace: NF98U110M5CAHRI reference: 21543821016.007.80174002.12EPA 3627599
NCHC51CT5D-**+TDR+ furnace: NF95X080S4C*AHRI reference: 21749124216.007.80176002.18EPA 4431942
NCUC36AT5D-**+TDR+ furnace: NF80U045T3A*AHRI reference: 21749100916.007.80174002.14EPA 4431955
NCUC50CT5D-**+TDR+ furnace: NF96U110V5C*AHRI reference: 21749135216.007.80174002.12EPA 4431994
NCUC50CT5D-**+TDR+ furnace: NF96U090V3C*AHRI reference: 21749132816.007.80173002.12EPA 4432008
NCUC36BT5D-**+TDR+ furnace: NF95X060S3B*AHRI reference: 21749123816.007.80171002.12EPA 4432907
NCUC36AT5D-**+TDR+ furnace: NF80U045S3A*AHRI reference: 21749099816.007.80170002.12EPA 4432966
NCUC50CT5D-**+TDR+ furnace: NF95X100S5C*AHRI reference: 21749124916.007.80172002.12EPA 4432977
NCHC42CT5D-**+TDR+ furnace: NF80U110V5C*AHRI reference: 21749113216.008.00182002.18EPA 4433033
NCHC51CT5D-**+TDR+ furnace: NF80U110V5C*AHRI reference: 21749113316.008.00179002.20EPA 4433034
NCUC36AT5D-**+TDR+ furnace: NF80L045S3A*AHRI reference: 21749094116.007.80170002.12EPA 4433041
NCUC36AT5D-**+TDR+ furnace: NF80U070S3A*AHRI reference: 21749101916.007.80172002.12EPA 4433046
NCUC36AT5D-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21749104316.007.80170002.12EPA 4433059
NCUC36AT5D-**+TDR+ furnace: NF80L070S3A*AHRI reference: 21749095116.007.80172002.12EPA 4433077
NCHC42BT5D-**+TDR+ furnace: NF80U090V4B*AHRI reference: 21749110416.008.10186002.26EPA 4433093
NCDC36CT5D-**+TDR+ furnace: NF96D090S4C*AHRI reference: 21749126116.008.00187002.16EPA 4433098
NCHC42BT5D-**+TDR+ furnace: NF80L070S3B*AHRI reference: 21749096216.008.10184002.24EPA 4433103
NCHC48BT5D-**+TDR+ furnace: NF80L070S3B*AHRI reference: 21749096316.008.00173002.18EPA 4433104
NCHC42CT5D-**+TDR+ furnace: NF96U090V5C*AHRI reference: 21749133316.008.10184002.18EPA 4433161