GE / AIR-SOURCE HEAT PUMP

NS17H36SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 11

324 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,200–36,000BTU/h

Each efficiency range summarizes published EPA records for NS17H36SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 324 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8324 / 324
EER2 · BTU/Wh12.2–14324 / 324
HSPF2 · BTU/Wh7.8–8.7324 / 324
Cooling capacity · BTU/h35,200–36,000324 / 324
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000324 / 324
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000324 / 324
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300324 / 324
COP at 5°F / −15°C2.08–2.34324 / 324
Equipment / loop typeHP - Split System324 / 324
Refrigerant / source-reported GWPR-410A (GWP:2088)324 / 324
Compressor stagingSingle stage324 / 324
Connected capabilityNo324 / 324

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC50/60CT4+TDR+ furnace: NF95X080S4C-*AHRI reference: 21026243015.807.80172002.10EPA 2455249
NAM36V1TA4AHRI reference: 21072048015.808.10174002.20EPA 2456491
NAM36V2TA4AHRI reference: 21067785815.808.50186002.32EPA 2457093
NCUC36AT4+TDR+ furnace: NF80X060S3A-*AHRI reference: 21026240715.807.80170002.08EPA 2457565
NCUC36BT4+TDR+ furnace: NF97X060V3B-*AHRI reference: 21026242715.807.80174002.12EPA 2459820
NCUC36BT4+TDR+ furnace: NF96U070S3B-*AHRI reference: 21026242315.807.80170002.08EPA 2460013
NCUU36AP4+TDR+TXV+ furnace: NF80X060S3A-*AHRI reference: 21026235115.807.80170002.08EPA 2460045
NCUC50/60CT4+TDR+ furnace: NF97U090M5C-*AHRI reference: 21026244615.807.80176002.12EPA 2460260
NCHC48BT4+TDR+ furnace: NF80U090V4B-*AHRI reference: 21026238315.808.00176002.22EPA 2460312
NCUC36BT4+TDR+ furnace: NF95X040S3B-*AHRI reference: 21026241615.807.80170002.12EPA 2461109
NCUC36AT4+TDR+ furnace: NF80U070V3A-*AHRI reference: 21026241415.807.80174002.10EPA 2461114
NCUC36AT4+TDR+ furnace: NF80X040S3A-*AHRI reference: 21026240615.807.80170002.08EPA 2461336
NCUC36BT4+TDR+ furnace: NF97U070M3B-*AHRI reference: 21026242815.807.80174002.12EPA 2461339
NCUC50/60CT4+TDR+ furnace: NF80U110V5C-*AHRI reference: 21026244115.807.80174002.10EPA 2461367
NCUU36BP4+TDR+TXV+ furnace: NF96U070S3B-*AHRI reference: 21026236715.807.80170002.08EPA 2461789
NCHC48BT4+TDR+ furnace: NF80X080S4B-*AHRI reference: 21026237315.807.80172002.18EPA 2461796
NCUC50/60CT4+TDR+ furnace: NF97X080V5C-*AHRI reference: 21026244315.807.80174002.10EPA 2461806
NCUU36BP4+TDR+TXV+ furnace: NF97X060V3B-*AHRI reference: 21026237115.807.80174002.12EPA 2461809
NCHC48BT4+TDR+ furnace: NF95X060S3B-*AHRI reference: 21026237515.807.80172002.18EPA 2462003
NCUU36AP4+TDR+TXV+ furnace: NF80U070V3A-*AHRI reference: 21026235815.807.80174002.10EPA 2462005

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →