GE / AIR-SOURCE HEAT PUMP

NS17H30SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 5

254 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for NS17H30SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 254 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2254 / 254
EER2 · BTU/Wh12.2–13.5254 / 254
HSPF2 · BTU/Wh7.8–8.6254 / 254
Cooling capacity · BTU/h28,200–30,000254 / 254
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000254 / 254
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600254 / 254
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400254 / 254
COP at 5°F / −15°C1.96–2.38254 / 254
Equipment / loop typeHP - Split System254 / 254
Refrigerant / source-reported GWPR-410A (GWP:2088)254 / 254
Compressor stagingSingle stage254 / 254
Connected capabilityNo254 / 254

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC30BT4+TDR+ furnace: NF80X080V4B-*AHRI reference: 21026232115.808.10143002.20EPA 2461363 →
NCHC30AT4+TDR+ furnace: NF80X060V3A-*AHRI reference: 21026228115.807.80139002.00EPA 2461515 →
NCUC36AT4+TDR+ furnace: NF80U070V3A-*AHRI reference: 21026233415.808.10144002.26EPA 2461533 →
NCHC30AT4+TDR+ furnace: NF80U045T3A-*AHRI reference: 21026227615.807.80138002.00EPA 2461548 →
NCUU36BP4+TDR+TXV+ furnace: NF97X060V3B-*AHRI reference: 21026227215.808.10144002.26EPA 2461561 →
NCUC30AT4+TDR+ furnace: NF80U045T3A-*AHRI reference: 21026230415.808.10143002.24EPA 2461767 →
NCUU36AP4+TDR+TXV+ furnace: NF80X060S3A-*AHRI reference: 21026225215.808.00144002.26EPA 2461770 →
NCUC30BT4+TDR+ furnace: NF80U070S3B-*AHRI reference: 21026231715.808.00144002.22EPA 2461780 →
NCUU30AP4+TDR+TXV+ furnace: NF80U045S3A-*AHRI reference: 21026223115.808.00141002.20EPA 2461823 →
NCUC36AT4+TDR+ furnace: NF80X060S3A-*AHRI reference: 21026232715.808.00144002.26EPA 2462308 →
NCUC36AT4+TDR+ furnace: NF80X040S3A-*AHRI reference: 21026232615.808.00144002.26EPA 2462314 →
NCUU36AP4+TDR+TXV+ furnace: NF80U070V3A-*AHRI reference: 21026225915.808.10144002.26EPA 2462317 →
NCDC42BT4+TDR+ furnace: NF80D090T4B-*AHRI reference: 21335582415.808.60151002.32EPA 2841302 →
NCDC42BT4+TDR+ furnace: NF80D070S3B-*AHRI reference: 21335582515.808.60153002.34EPA 2841303 →
NCHC30BT4+TDR+ furnace: NF97U070V3BAHRI reference: 21528333515.808.00137002.08EPA 3619420 →
NCHC30BT5D-**+TDR+ furnace: NF97U070V3BAHRI reference: 21528333915.808.00137002.08EPA 3619422 →
NCDC42BT5D-**+TDR+ furnace: NF80D070S3B*AHRI reference: 21749092215.808.60153002.34EPA 4432017 →
NCDC42BT5D-**+TDR+ furnace: NF80D090T4B*AHRI reference: 21749092715.808.60151002.32EPA 4432022 →
NCHC30BT5D-**+TDR+ furnace: NF96U070V3B*AHRI reference: 21749131015.808.00137002.08EPA 4432029 →
NCHC30BT5D-**+TDR+ furnace: NF95X060S3B*AHRI reference: 21749123315.807.80138002.08EPA 4432036 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →