GE / AIR-SOURCE HEAT PUMP

NS17H30SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 13

254 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for NS17H30SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 254 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2254 / 254
EER2 · BTU/Wh12.2–13.5254 / 254
HSPF2 · BTU/Wh7.8–8.6254 / 254
Cooling capacity · BTU/h28,200–30,000254 / 254
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000254 / 254
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600254 / 254
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400254 / 254
COP at 5°F / −15°C1.96–2.38254 / 254
Equipment / loop typeHP - Split System254 / 254
Refrigerant / source-reported GWPR-410A (GWP:2088)254 / 254
Compressor stagingSingle stage254 / 254
Connected capabilityNo254 / 254

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUU30BP4+TDR+TXV+ furnace: NF80X080S4B-*AHRI reference: 21026223615.208.00147002.16EPA 2454975 →
NCHC30AT4+TDR+ furnace: NF80X060S3A-*AHRI reference: 21026227515.207.80141001.96EPA 2455049 →
NCUC30BT4+TDR+ furnace: NF80X080S4B-*AHRI reference: 21026231115.208.00147002.16EPA 2455072 →
NCHC36CT4+TDR+ furnace: NF97U110M5C-*AHRI reference: 21026230115.208.50152002.22EPA 2460276 →
NCHC30AT4+TDR+ furnace: NF80X040S3A-*AHRI reference: 21026227415.207.80141001.96EPA 2462042 →
NCHC36CT5D-**+TDR+ furnace: NF97U110V5CAHRI reference: 21528335215.208.50152002.22EPA 3619408 →
NCHC36CT4+TDR+ furnace: NF97U110V5CAHRI reference: 21528334515.208.50152002.22EPA 3619424 →
NCHC36CT4+TDR+ furnace: NF98U110M5CAHRI reference: 21543819115.208.50152002.22EPA 3627546 →
NCHC36CT5D-**+TDR+ furnace: NF96U110V5C*AHRI reference: 21749134815.208.50152002.22EPA 4431990 →
NCUC30BT5D-**+TDR+ furnace: NF80X080S4B*AHRI reference: 21749117615.208.00147002.16EPA 4433021 →
NCHC30AT5D-**+TDR+ furnace: NF80X040S3A*AHRI reference: 21749114615.207.80141001.96EPA 4433052 →
NCHC36CT5D-**+TDR+ furnace: NF97U110M5C*AHRI reference: 21749143715.208.50152002.22EPA 4433322 →
NCHC30AT5D-**+TDR+ furnace: NF80X060S3A*AHRI reference: 21749115715.207.80141001.96EPA 4433361 →
NCHC36CT5D-**+TDR+ furnace: NF97U110V5C*AHRI reference: 21749144215.208.50152002.22EPA 4433366 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →