GE / AIR-SOURCE HEAT PUMP

NS17H24SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 6

259 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–24,000BTU/h

Each efficiency range summarizes published EPA records for NS17H24SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 259 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17259 / 259
EER2 · BTU/Wh12.5–14259 / 259
HSPF2 · BTU/Wh7.8–8.2259 / 259
Cooling capacity · BTU/h22,600–24,000259 / 259
Heating capacity at 47°F / 8.3°C · BTU/h21,200–22,600259 / 259
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700259 / 259
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500259 / 259
COP at 5°F / −15°C2–2.16259 / 259
Equipment / loop typeHP - Split System259 / 259
Refrigerant / source-reported GWPR-410A (GWP:2088)259 / 259
Compressor stagingSingle stage259 / 259
Connected capabilityNo259 / 259

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC30BT5D-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21749140016.407.80104002.06EPA 4433137
NCHC24AT5D-**+TDR+ furnace: NF80U045T3A*AHRI reference: 21749100216.407.80102002.04EPA 4433166
NCUC24AT5D-**+TDR+ furnace: NF80U045T3A*AHRI reference: 21749100416.407.80102002.04EPA 4433168
NCUC30AT5D-**+TDR+ furnace: NF80U045T3A*AHRI reference: 21749100516.407.80102002.06EPA 4433169
NCUC24BT5D-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21749105816.407.80104002.08EPA 4433196
NCUC24BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749118616.407.80104002.04EPA 4433204
NCUC30BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749118716.407.80104002.06EPA 4433205
NCUC24BT5D-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21749096916.407.80104002.08EPA 4433211
NCHC24AT5D-**+TDR+ furnace: NF80X060V3A*AHRI reference: 21749116416.407.80104002.10EPA 4433235
NCUC24AT5D-**+TDR+ furnace: NF80X060V3A*AHRI reference: 21749116616.407.80104002.08EPA 4433237
NCUC24BT5D-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21749102516.407.80104002.04EPA 4433240
NCUC30BT5D-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21749102616.407.80104002.06EPA 4433241
NCUC24BT5D-**+TDR+ furnace: NF97U070M3B*AHRI reference: 21749138616.407.80104002.04EPA 4433266
NCUC30BT5D-**+TDR+ furnace: NF97U070M3B*AHRI reference: 21749138716.407.80104002.06EPA 4433364
NCUC24BT5D-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21749139916.407.80104002.04EPA 4433365
NCUC24AT4+TDR+ furnace: NF80L070S3A-*AHRI reference: 21026210516.207.80104002.02EPA 2471108
NCUC24AT4+TDR+ furnace: NF80U070S3A-*AHRI reference: 21026210416.207.80104002.02EPA 2471109
NCUC24AT4+TDR+ furnace: NF80U070V3A-*AHRI reference: 21026210716.207.80104002.04EPA 2471113
NAM24V2TA4AHRI reference: 21067785516.208.10106002.16EPA 2471114
NCUC30AT4+TDR+ furnace: NF80U045S3A-*AHRI reference: 21026212716.207.80102002.02EPA 2471115

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →