GE / AIR-SOURCE HEAT PUMP

NS17H24SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 11

259 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–24,000BTU/h

Each efficiency range summarizes published EPA records for NS17H24SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 259 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17259 / 259
EER2 · BTU/Wh12.5–14259 / 259
HSPF2 · BTU/Wh7.8–8.2259 / 259
Cooling capacity · BTU/h22,600–24,000259 / 259
Heating capacity at 47°F / 8.3°C · BTU/h21,200–22,600259 / 259
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700259 / 259
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500259 / 259
COP at 5°F / −15°C2–2.16259 / 259
Equipment / loop typeHP - Split System259 / 259
Refrigerant / source-reported GWPR-410A (GWP:2088)259 / 259
Compressor stagingSingle stage259 / 259
Connected capabilityNo259 / 259

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC30AT5D-**+TDR+ furnace: NF80X040S3A*AHRI reference: 21749114516.007.80106002.04EPA 4433051
NCUC24BT5D-**+TDR+ furnace: NF80U090V4B*AHRI reference: 21749109916.007.80104002.04EPA 4433088
NCUC30BT5D-**+TDR+ furnace: NF80U090V4B*AHRI reference: 21749110016.007.80104002.00EPA 4433089
NCHC30AT5D-**+TDR+ furnace: NF80X060S3A*AHRI reference: 21749115416.008.10105002.10EPA 4433119
NCUC24AT5D-**+TDR+ furnace: NF80X060S3A*AHRI reference: 21749115516.007.80106002.02EPA 4433120
NCUC30AT5D-**+TDR+ furnace: NF80X060S3A*AHRI reference: 21749115616.007.80106002.04EPA 4433121
NCUC24BT5D-**+TDR+ furnace: NF96U045V3B*AHRI reference: 21749128216.007.80104002.02EPA 4433283
NCHC30BT5D-**+TDR+ furnace: NF95X060S3B*AHRI reference: 21749123016.007.80108002.02EPA 4433302
NCUC24AT5D-**+TDR+ furnace: NF80U070T3A*AHRI reference: 21749103916.007.80106002.02EPA 4433358
NCHC30BT5D-**+TDR+ furnace: NF96U070S3B*AHRI reference: 21749129416.007.80108002.04EPA 4433368
NCUC30AT4+TDR+ furnace: NF80U070T3A-*AHRI reference: 21026212615.807.80106002.04EPA 2471102
NCUC24BT4+TDR+ furnace: NF80X080S4B-*AHRI reference: 21026210815.807.80106002.02EPA 2471107
NCUC30BT4+TDR+ furnace: NF80X080S4B-*AHRI reference: 21026213215.807.80106002.04EPA 2471110
NAM24V1TA4AHRI reference: 21072047815.808.00108002.12EPA 2472130
NCHC24AT4+TDR+ furnace: NF80X060S3A-*AHRI reference: 21026206715.807.80106002.04EPA 2634869
NCUU30BP4+TDR+TXV+ furnace: NF80X080S4B-*AHRI reference: 21026205115.807.80106002.04EPA 2634871
NCHC24AT4+TDR+ furnace: NF80X040S3A-*AHRI reference: 21026206615.807.80106002.04EPA 2634883
NCUU24BP4+TDR+TXV+ furnace: NF80X080S4B-*AHRI reference: 21026202715.807.80106002.02EPA 2634884
NCUU30AP4+TDR+TXV+ furnace: NF80U070T3A-*AHRI reference: 21026204515.807.80106002.04EPA 2634887
NCHC24AT5D-**+TDR+ furnace: NF80X040S3A*AHRI reference: 21749114215.807.80106002.04EPA 4431968

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →