GE / AIR-SOURCE HEAT PUMP

NS17H24SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series

259 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–24,000BTU/h

Each efficiency range summarizes published EPA records for NS17H24SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 259 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17259 / 259
EER2 · BTU/Wh12.5–14259 / 259
HSPF2 · BTU/Wh7.8–8.2259 / 259
Cooling capacity · BTU/h22,600–24,000259 / 259
Heating capacity at 47°F / 8.3°C · BTU/h21,200–22,600259 / 259
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700259 / 259
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500259 / 259
COP at 5°F / −15°C2–2.16259 / 259
Equipment / loop typeHP - Split System259 / 259
Refrigerant / source-reported GWPR-410A (GWP:2088)259 / 259
Compressor stagingSingle stage259 / 259
Connected capabilityNo259 / 259

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCHC30BT4+TDR+ furnace: NF80U090S4B-*AHRI reference: 21026209117.008.00104002.10EPA 2471125 →
NCHC30BT4+TDR+ furnace: NF80U090T4B-*AHRI reference: 21026208717.008.00103002.06EPA 2634892 →
NCHC30BT5D-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21749108417.008.00103002.06EPA 4431936 →
NCHC30BT5D-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21749096817.008.00104002.10EPA 4433156 →
NCHC30BT5D-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21749105717.008.00104002.10EPA 4433195 →
NCHC30BT4+TDR+ furnace: NF80X080V4B-*AHRI reference: 21026209416.808.00104002.10EPA 2471124 →
NCHC30BT4+TDR+ furnace: NF80U070S3B-*AHRI reference: 21026209016.808.00104002.06EPA 2471126 →
NCHC30AT4+TDR+ furnace: NF80X060V3A-*AHRI reference: 21026208216.808.10104002.14EPA 2471130 →
NCHC30BT4+TDR+ furnace: NF97U070M3B-*AHRI reference: 21026209816.807.80104002.08EPA 2471745 →
NCHC30BT4+TDR+ furnace: NF97U070V3BAHRI reference: 21528329616.807.80104002.08EPA 3619267 →
NCHC30BT5D-**+TDR+ furnace: NF97U070V3BAHRI reference: 21528330116.807.80104002.08EPA 3619269 →
NCHC30BT4+TDR+ furnace: NF98U070M3BAHRI reference: 21543818316.807.80104002.08EPA 3627539 →
NCHC30BT5D-**+TDR+ furnace: NF96U070V3B*AHRI reference: 21749130716.807.80104002.08EPA 4432026 →
NCHC30BT5D-**+TDR+ furnace: NF80L070S3B*AHRI reference: 21749095616.808.00104002.06EPA 4432948 →
NCHC30BT5D-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21749102416.808.00104002.06EPA 4433050 →
NCHC30BT5D-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21749139816.807.80104002.08EPA 4433136 →
NCHC30BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749118516.808.00104002.10EPA 4433203 →
NCHC30AT5D-**+TDR+ furnace: NF80X060V3A*AHRI reference: 21749116516.808.10104002.14EPA 4433236 →
NCHC30BT5D-**+TDR+ furnace: NF97U070M3B*AHRI reference: 21749138516.807.80104002.08EPA 4433363 →
NCUC30AT4+TDR+ furnace: NF80X060V3A-*AHRI reference: 21026213016.608.00102002.08EPA 2471099 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →