GE / AIR-SOURCE HEAT PUMP

NS17H18SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 6

257 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for NS17H18SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8257 / 257
EER2 · BTU/Wh12.2–14257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h18,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100257 / 257
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700257 / 257
COP at 5°F / −15°C1.9–2.16257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUU30BP4+TDR+TXV+ furnace: NF96U070S3B-*AHRI reference: 21026192516.407.8077001.98EPA 2461738
NCUU30BP4+TDR+TXV+ furnace: NF80U090V4B-*AHRI reference: 21026192716.408.0080001.96EPA 2461753
NCHC24BT4+TDR+ furnace: NF97X040V3B-*AHRI reference: 21026195216.408.1084002.08EPA 2462290
NCHC24BT4+TDR+ furnace: NF97X060V3B-*AHRI reference: 21026195316.408.1084002.08EPA 2462293
NCHC24AT4+TDR+ furnace: NF80U045S3A-*AHRI reference: 21026193516.408.0080002.06EPA 2462296
NCHC30BT4+TDR+ furnace: NF96U070S3B-*AHRI reference: 21026196416.407.8077002.00EPA 2462298
NCHC24BT4+TDR+ furnace: NF80U070S3B-*AHRI reference: 21026194616.408.1082002.10EPA 2462300
NCUC30BT4+TDR+ furnace: NF96U070S3B-*AHRI reference: 21026201216.407.8077001.98EPA 2462312
NCDC3036BT4+TDR+ furnace: NF96D045S3B-*AHRI reference: 21335581116.408.3087002.10EPA 2841287
NCHC24BT4+TDR+ furnace: NF97U045V3BAHRI reference: 21528324716.408.1084002.06EPA 3619254
NCHC24BT4+TDR+ furnace: NF97U070V3BAHRI reference: 21528324916.408.1084002.10EPA 3619255
NCHC24BT5D-**+TDR+ furnace: NF97U045V3BAHRI reference: 21528325116.408.1084002.06EPA 3619256
NCHC24BT5D-**+TDR+ furnace: NF97U070V3BAHRI reference: 21528325316.408.1084002.10EPA 3619257
NCUC24BT4+TDR+ furnace: NF97U070V3BAHRI reference: 21528326616.408.1084002.08EPA 3619402
NCUC30BT4+TDR+ furnace: NF97U045V3BAHRI reference: 21528327316.408.0078002.00EPA 3619404
NCUC30BT5D-**+TDR+ furnace: NF97U045V3BAHRI reference: 21528327716.408.0078002.00EPA 3619406
NCUU24BP4+TDR+TXV+ furnace: NF97U070V3BAHRI reference: 21528328316.408.1084002.08EPA 3619416
NCUU30BP4+TDR+TXV+ furnace: NF97U045V3BAHRI reference: 21528328616.408.0078002.00EPA 3619417
NCUC24BT5D-**+TDR+ furnace: NF97U070V3BAHRI reference: 21528327116.408.1084002.08EPA 3619439
NCHC24BT4+TDR+ furnace: NF98U070M3BAHRI reference: 21543817716.408.1084002.10EPA 3627533

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →