GE / AIR-SOURCE HEAT PUMP

NS17H18SA4-**A

NS17 Series · NS17H · NS17H SERIES · NS17H Series · source records, page 3

257 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for NS17H18SA4-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8257 / 257
EER2 · BTU/Wh12.2–14257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h18,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100257 / 257
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700257 / 257
COP at 5°F / −15°C1.9–2.16257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC30BT5D-**+TDR+ furnace: NF97U070V3B*AHRI reference: 21749139716.808.0078002.00EPA 4433135 →
NCHC30BT5D-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21749146216.808.1078002.02EPA 4433151 →
NCHC30BT5D-**+TDR+ furnace: NF96U070V3B*AHRI reference: 21749130416.808.0078002.00EPA 4433226 →
NCHC30BT5D-**+TDR+ furnace: NF97U070M3B*AHRI reference: 21749138216.808.0078002.00EPA 4433232 →
NCHC24AT5D-**+TDR+ furnace: NF80X060V3A*AHRI reference: 21749116116.808.1082002.06EPA 4433233 →
NCHC24BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749118116.808.1084002.10EPA 4433252 →
NCHC30BT5D-**+TDR+ furnace: NF80X080V4B*AHRI reference: 21749118216.808.1080002.00EPA 4433253 →
NCUC30BT5D-**+TDR+ furnace: NF97U070M3B*AHRI reference: 21749138416.808.0078002.00EPA 4433265 →
NCHC30BT5D-**+TDR+ furnace: NF97X040V3B*AHRI reference: 21749144916.808.0078002.02EPA 4433333 →
NCUC30BT5D-**+TDR+ furnace: NF97X040V3B*AHRI reference: 21749145116.808.0078002.00EPA 4433335 →
NCUC30BT5D-**+TDR+ furnace: NF97X060V3B*AHRI reference: 21749146416.808.0078002.00EPA 4433340 →
NCUC30AT5D-**+TDR+ furnace: NF80X060V3A*AHRI reference: 21749116316.808.0079002.02EPA 4433360 →
NCUC30BT5D-**+TDR+ furnace: NF80U070S3B*AHRI reference: 21749102316.807.8077001.98EPA 4433373 →
NCHC30BT4+TDR+ furnace: NF95X060S3B-*AHRI reference: 21026195716.607.8076002.00EPA 2459976 →
NCUC30AT4+TDR+ furnace: NF80U070V3A-*AHRI reference: 21026200216.608.0080001.98EPA 2460002 →
NCUC24AT4+TDR+ furnace: NF80X060V3A-*AHRI reference: 21026197716.608.1081002.10EPA 2461508 →
NCUU24AP4+TDR+TXV+ furnace: NF80X060V3A-*AHRI reference: 21026189016.608.1081002.10EPA 2461760 →
NCUU30AP4+TDR+TXV+ furnace: NF80U070V3A-*AHRI reference: 21026191516.608.0080001.98EPA 2461777 →
NCHC30BT4+TDR+ furnace: NF97U045V3BAHRI reference: 21528325616.608.0078002.00EPA 3619258 →
NCHC30BT5D-**+TDR+ furnace: NF97U045V3BAHRI reference: 21528326016.608.0078002.00EPA 3619260 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →