GE / AIR-SOURCE HEAT PUMP

NS16H42SA5-**A

NS16H Series

42 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity41,000–42,000BTU/h

Each efficiency range summarizes published EPA records for NS16H42SA5-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 42 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.542 / 42
EER2 · BTU/Wh12.6–13.242 / 42
HSPF2 · BTU/Wh7.8–8.242 / 42
Cooling capacity · BTU/h41,000–42,00042 / 42
Heating capacity at 47°F / 8.3°C · BTU/h39,000–40,50042 / 42
Heating capacity at 17°F / −8.3°C · BTU/h24,600–25,80042 / 42
Heating capacity at 5°F / −15°C · BTU/h19,400–20,80042 / 42
COP at 5°F / −15°C2–2.1442 / 42
Equipment / loop typeHP - Split System42 / 42
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)42 / 42
Compressor stagingSingle stage42 / 42
Connected capabilityNo42 / 42

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCU[C,U]49CT5*-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21649765015.508.00194002.06EPA 3847230
NCU[C,U]49CT5*-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21649765115.508.00197002.08EPA 3847231
NCU[C,U]49CT5*-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21649765215.507.80195002.06EPA 3847232
NCU[C,U]49CT5*-**+TDR+ furnace: NF96U110S5C*AHRI reference: 21649765515.507.80195002.06EPA 3847282
NCU[C,U]49CT5*-**+TDR+ furnace: NF97U110V5C*AHRI reference: 21649765615.507.80196002.04EPA 3847283
NCU[C,U]49CT5*-**+TDR+ furnace: NF80X100V5C*AHRI reference: 21649765715.507.80196002.04EPA 3847284
NCU[C,U]49CT5*-**+TDR+ furnace: NF97X080V4C*AHRI reference: 21649765815.507.80196002.04EPA 3847285
NCU[C,U]48CT5*-**+TDR+ furnace: NF80L110S5C*AHRI reference: 21649763715.507.80204002.10EPA 3847291
NCU[C,U]49CT5*-**+TDR+ furnace: NF98U090M4C*AHRI reference: 21649766115.507.80196002.04EPA 3847312
NCU[C,U]49CT5*-**+TDR+ furnace: NF98U110M5C*AHRI reference: 21649766315.507.80196002.04EPA 3847314
NAM42V1TA5*-**AHRI reference: 21649762815.507.80206002.00EPA 3847333
NCHC42BT5*-**+TDR+ furnace: NF80U090T4B*AHRI reference: 21649767015.507.80195002.04EPA 3847334
NCHC42BT5*-**+TDR+ furnace: NF80U090S4B*AHRI reference: 21649767115.507.80194002.04EPA 3847335
NCHC42BT5*-**+TDR+ furnace: NF80L090S4B*AHRI reference: 21649767215.507.80194002.04EPA 3847336
NCU[C,U]48CT5*-**+TDR+ furnace: NF80U110T5C*AHRI reference: 21649763415.507.80204002.12EPA 3847384
NCU[C,U]48CT5*-**+TDR+ furnace: NF80U090S5C*AHRI reference: 21649763515.507.80206002.12EPA 3847385
NCU[C,U]48CT5*-**+TDR+ furnace: NF80U110S5C*AHRI reference: 21649763615.507.80204002.10EPA 3847386
NCU[C,U]49CT5*-**+TDR+ furnace: NF80L110S5C*AHRI reference: 21649765315.507.80195002.06EPA 3847398
NCU[C,U]48CT5*-**+TDR+ furnace: NF96U110S5C*AHRI reference: 21649763915.507.80204002.10EPA 3847400
NCU[C,U]49CT5*-**+TDR+ furnace: NF97U110T5C*AHRI reference: 21815978915.507.80199002.06EPA 4577822

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →