NS18H60HA5***
Connect · source records, page 9
352 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS18H60HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 352 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.3 | 352 / 352 |
| EER2 · BTU/Wh | 9.6–11.7 | 352 / 352 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 352 / 352 |
| Cooling capacity · BTU/h | 42,500–55,500 | 352 / 352 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 352 / 352 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 352 / 352 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 352 / 352 |
| COP at 5°F / −15°C | 1.75–1.95 | 352 / 352 |
| Equipment / loop type | HP - Split System | 352 / 352 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 352 / 352 |
| Compressor staging | Continuously variable | 352 / 352 |
| Connected capability | No | 352 / 352 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCDC48CT5****+TDR+ furnace: NF97D090V5C***Cold climate designationAHRI reference: 216743606 | 16.50 | 9.00 | 40000 | 1.85 | EPA 3893304 → |
NCUC48CT5****+TDR+ furnace: NF98U090M5C***Cold climate designationAHRI reference: 217124165 | 16.50 | 8.50 | 40000 | 1.80 | EPA 4003641 → |
NCHC42CT5****+TDR+ furnace: NF95X080S4C***Cold climate designationAHRI reference: 217124187 | 16.50 | 8.50 | 39500 | 1.80 | EPA 4004662 → |
NCUC60CT5****+TDR+ furnace: NF80U110V5C***Cold climate designationAHRI reference: 217124215 | 16.50 | 8.50 | 40500 | 1.90 | EPA 4004686 → |
NCUC60CT5****+TDR+ furnace: NF80X080V4B***Cold climate designationAHRI reference: 217124216 | 16.50 | 8.50 | 40500 | 1.90 | EPA 4004688 → |
NCUC60CT5****+TDR+ furnace: NF96U110S5C***Cold climate designationAHRI reference: 217124226 | 16.50 | 8.50 | 40500 | 1.90 | EPA 4004698 → |
NCDC48CT5****+TDR+ furnace: NF96D090V5C***Cold climate designationAHRI reference: 217177725 | 16.50 | 9.00 | 40000 | 1.85 | EPA 4006883 → |
NCUC48CT5****+TDR+ furnace: NF96U090V4CF***Cold climate designationAHRI reference: 217313742 | 16.50 | 8.50 | 39500 | 1.80 | EPA 4028865 → |
NCUC60CT5****+TDR+ furnace: NF80L110V5CF***Cold climate designationAHRI reference: 217313965 | 16.50 | 8.50 | 40500 | 1.90 | EPA 4029014 → |
NCHC60DT5****+TDR+ furnace: NF80U135V5DF***Cold climate designationAHRI reference: 217314013 | 16.50 | 8.50 | 40000 | 1.85 | EPA 4029054 → |
NCDC60DT5****+TDR+ furnace: NF80D110V5CF***Cold climate designationAHRI reference: 217314038 | 16.50 | 8.50 | 40500 | 1.90 | EPA 4029063 → |
NCUC60CT5****+TDR+ furnace: NF97X080V5C***Cold climate designationAHRI reference: 216743608 | 16.45 | 8.50 | 40500 | 1.90 | EPA 3893306 → |
NCUC48CT5****+TDR+ furnace: NF98U090M4C***Cold climate designationAHRI reference: 217124153 | 16.45 | 8.50 | 40000 | 1.80 | EPA 4003629 → |
NCHC51CT5****+TDR+ furnace: NF98U110M5C***Cold climate designationAHRI reference: 217124236 | 16.45 | 8.50 | 41000 | 1.85 | EPA 4004708 → |
NCHC60DT5****+TDR+ furnace: NF98U135M5D***Cold climate designationAHRI reference: 217124240 | 16.45 | 8.50 | 40500 | 1.85 | EPA 4004712 → |
NCHC42BT5****+TDR+ furnace: NF80X080V4BF***Cold climate designationAHRI reference: 217313808 | 16.45 | 9.00 | 39000 | 1.90 | EPA 4028962 → |
NCHC42CT5****+TDR+ furnace: NF80U110V5CF***Cold climate designationAHRI reference: 217313846 | 16.45 | 8.50 | 39500 | 1.80 | EPA 4028988 → |
NCHC48BT5****+TDR+ furnace: NF80X080V4BF***Cold climate designationAHRI reference: 217313860 | 16.45 | 9.00 | 40000 | 1.80 | EPA 4028994 → |
NCHC48CT5****+TDR+ furnace: NF93U110S4CF***Cold climate designationAHRI reference: 217313884 | 16.45 | 8.50 | 39500 | 1.80 | EPA 4029024 → |
NCDC48CT5****+TDR+ furnace: NF99D090V5CF***Cold climate designationAHRI reference: 217313930 | 16.45 | 9.00 | 40000 | 1.85 | EPA 4029034 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →