NS18H60HA5***
Connect · source records, page 15
352 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS18H60HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 352 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.3 | 352 / 352 |
| EER2 · BTU/Wh | 9.6–11.7 | 352 / 352 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 352 / 352 |
| Cooling capacity · BTU/h | 42,500–55,500 | 352 / 352 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 352 / 352 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 352 / 352 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 352 / 352 |
| COP at 5°F / −15°C | 1.75–1.95 | 352 / 352 |
| Equipment / loop type | HP - Split System | 352 / 352 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 352 / 352 |
| Compressor staging | Continuously variable | 352 / 352 |
| Connected capability | No | 352 / 352 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCHC60DT5****+TDR+ furnace: NF80U135S5D***Cold climate designationAHRI reference: 217124261 | 16.00 | 8.10 | 40500 | 1.85 | EPA 4004731 → |
NCHC48CT5****+TDR+ furnace: NF97U090V5C***Cold climate designationAHRI reference: 217124258 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4004733 → |
NCUC5060CT5****+TDR+ furnace: NF80U090S5C***Cold climate designationAHRI reference: 217165811 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4004734 → |
NCUC5060CT5****+TDR+ furnace: NF80U110S5C***Cold climate designationAHRI reference: 217165812 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4004735 → |
NCUC5060CT5****+TDR+ furnace: NF98U110M5C***Cold climate designationAHRI reference: 217165821 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4004740 → |
NCUC5060CT5****+TDR+ furnace: NF97U110V5C***Cold climate designationAHRI reference: 217165824 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4004744 → |
NCDC5060CT5****+TDR+ furnace: NF97D110M5C***Cold climate designationAHRI reference: 217165827 | 16.00 | 8.50 | 41000 | 1.85 | EPA 4004746 → |
NCDC5060CT5****+TDR+ furnace: NF97D090V5C***Cold climate designationAHRI reference: 217165828 | 16.00 | 8.50 | 41000 | 1.90 | EPA 4004747 → |
NCDC5060CT5****+TDR+ furnace: NF97D110V5C***Cold climate designationAHRI reference: 217165829 | 16.00 | 8.50 | 41000 | 1.90 | EPA 4004748 → |
NCHC48CT5****+TDR+ furnace: NF96U110V5C***Cold climate designationAHRI reference: 217177723 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4006881 → |
NCDC42BT5****+TDR+ furnace: NF96D070V4B***Cold climate designationAHRI reference: 217177724 | 16.00 | 9.00 | 40000 | 1.85 | EPA 4006882 → |
NCDC60DT5****+TDR+ furnace: NF96D090V5C***Cold climate designationAHRI reference: 217177733 | 16.00 | 8.50 | 40500 | 1.90 | EPA 4006891 → |
NCDC60DT5****+TDR+ furnace: NF96D110V5C***Cold climate designationAHRI reference: 217177734 | 16.00 | 8.50 | 41000 | 1.90 | EPA 4006892 → |
NCUC48BT5****+TDR+ furnace: NF96U070S4BF***Cold climate designationAHRI reference: 217313726 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4028857 → |
NCHC42BT5****+TDR+ furnace: NF96U070S4BF***Cold climate designationAHRI reference: 217313817 | 16.00 | 9.00 | 39500 | 1.90 | EPA 4028966 → |
NCHC42CT5****+TDR+ furnace: NF80U110T3BF***Cold climate designationAHRI reference: 217313820 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4028967 → |
NCHC42CT5****+TDR+ furnace: NF96U110S5CF***Cold climate designationAHRI reference: 217313848 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4028987 → |
NCHC42CT5****+TDR+ furnace: NF97U110T5CF***Cold climate designationAHRI reference: 217313850 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4028989 → |
NCHC42CT5****+TDR+ furnace: NF96U090S5CF***Cold climate designationAHRI reference: 217313851 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4028990 → |
NCHC42CT5****+TDR+ furnace: NF93U110S5CF***Cold climate designationAHRI reference: 217313853 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4028991 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →