GE Appliances / AIR-SOURCE HEAT PUMP

NS18H60HA5***

Connect

352 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.3BTU/Wh
HSPF2 range8.1–9.6BTU/Wh
Cooling capacity42,500–55,500BTU/h

Each efficiency range summarizes published EPA records for NS18H60HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 352 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.3352 / 352
EER2 · BTU/Wh9.6–11.7352 / 352
HSPF2 · BTU/Wh8.1–9.6352 / 352
Cooling capacity · BTU/h42,500–55,500352 / 352
Heating capacity at 47°F / 8.3°C · BTU/h47,000–56,500352 / 352
Heating capacity at 17°F / −8.3°C · BTU/h38,000–45,000352 / 352
Heating capacity at 5°F / −15°C · BTU/h39,000–45,000352 / 352
COP at 5°F / −15°C1.75–1.95352 / 352
Equipment / loop typeHP - Split System352 / 352
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)352 / 352
Compressor stagingContinuously variable352 / 352
Connected capabilityNo352 / 352

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC49CT5****+TDR+ furnace: NF97U090V4CF***Cold climate designationAHRI reference: 21731377218.309.00390001.85EPA 4028946
NAM48V1TA5****Cold climate designationAHRI reference: 21586948318.009.50420001.75EPA 3716600
NAM42V2TA5****Cold climate designationAHRI reference: 21660475718.009.50425001.85EPA 3893005
NAM48E3TA5****Cold climate designationAHRI reference: 21670536618.009.50430001.85EPA 4028698
NAS48E1TB5****Cold climate designationAHRI reference: 21863594317.909.40445001.80EPA 4661149
NAS42E1TB5****Cold climate designationAHRI reference: 21863594217.909.60450001.80EPA 4661150
NCUC48CT5****+TDR+ furnace: NF97U090V4CF***Cold climate designationAHRI reference: 21731373417.809.00395001.80EPA 4028860
NCHC42CT5****+TDR+ furnace: NF97U090V4CF***Cold climate designationAHRI reference: 21731382717.809.00395001.80EPA 4028970
NCUC49CT5****+TDR+ furnace: NF80U090V5CF***Cold climate designationAHRI reference: 21731378217.709.00390001.85EPA 4028951
NCUC49CT5****+TDR+ furnace: NF80L090V5CF***Cold climate designationAHRI reference: 21731378517.709.00390001.85EPA 4028952
NCUC49CT5****+TDR+ furnace: NF80U110V5C***Cold climate designationAHRI reference: 21712416917.659.00390001.85EPA 4003644
NCUC49CT5****+TDR+ furnace: NF80L110V5CF***Cold climate designationAHRI reference: 21731378717.659.00390001.85EPA 4028953
NAM42E1TA5****Cold climate designationAHRI reference: 21660475417.609.00430001.80EPA 3893002
NAM42V1TA5****Cold climate designationAHRI reference: 21660475517.609.00430001.80EPA 3893003
NCUC49CT5****+TDR+ furnace: NF93U110S4CF***Cold climate designationAHRI reference: 21731377817.559.00390001.85EPA 4028949
NCHC42BT5****+TDR+ furnace: NF80U070V4BF***Cold climate designationAHRI reference: 21731381217.559.40390001.90EPA 4028964
NAM48E1TA5****Cold climate designationAHRI reference: 21660475617.509.00430001.80EPA 3893004
NAM48V2TA5****Cold climate designationAHRI reference: 21660475817.509.00430001.80EPA 3893006
NAM42E3TA5****Cold climate designationAHRI reference: 21670536517.509.40425001.85EPA 4028697
NCUC49CT5****+TDR+ furnace: NF80U110V5CF***Cold climate designationAHRI reference: 21731379217.509.00390001.85EPA 4028955

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →