| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.3 | 386 / 386 |
| EER2 · BTU/Wh | 10–12 | 386 / 386 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 386 / 386 |
| Cooling capacity · BTU/h | 32,200–36,200 | 386 / 386 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 386 / 386 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 386 / 386 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,600–30,800 | 386 / 386 |
| COP at 5°F / −15°C | 1.8–1.95 | 386 / 386 |
| Equipment / loop type | HP - Split System | 386 / 386 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 386 / 386 |
| Compressor staging | Continuously variable | 386 / 386 |
| Connected capability | No | 386 / 386 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCHC36CT5****+TDR+ furnace: NF93U110S4CF***Cold climate designationAHRI reference: 217313671 | 17.70 | 9.00 | 28200 | 1.90 | EPA 4028924 → |
NCU[C,U]36CT5****+TDR+ furnace: NF98U090M3C***Cold climate designationAHRI reference: 217663201 | 17.70 | 8.50 | 28400 | 1.85 | EPA 4498192 → |
NCUC37CT5****+TDR+ furnace: NF97U090T4C***Cold climate designationAHRI reference: 218668531 | 17.70 | 9.00 | 28800 | 1.90 | EPA 4670904 → |
NCUC30BT5****+TDR+ furnace: NF80U070S3B***Cold climate designationAHRI reference: 217124052 | 17.65 | 8.50 | 28600 | 1.85 | EPA 4003528 → |
NCUC30BT5****+TDR+ furnace: NF80L070S3B***Cold climate designationAHRI reference: 217124053 | 17.65 | 8.50 | 28600 | 1.85 | EPA 4003529 → |
NCUC36AT5****+TDR+ furnace: NF80L070S3A***Cold climate designationAHRI reference: 217124069 | 17.65 | 8.50 | 28400 | 1.85 | EPA 4003545 → |
NCUC36AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 217124070 | 17.65 | 8.50 | 28400 | 1.85 | EPA 4003546 → |
NCUC36BT5****+TDR+ furnace: NF80U090V4BF***Cold climate designationAHRI reference: 217313537 | 17.65 | 8.50 | 28400 | 1.85 | EPA 4028811 → |
NCUC36BT5****+TDR+ furnace: NF97U070T3BF***Cold climate designationAHRI reference: 217313511 | 17.65 | 8.50 | 28400 | 1.85 | EPA 4028828 → |
NCUC36AT5****+TDR+ furnace: NF80U045V3AF***Cold climate designationAHRI reference: 217313491 | 17.65 | 8.50 | 28400 | 1.85 | EPA 4028845 → |
NCHC30BT5****+TDR+ furnace: NF93U070S3BF***Cold climate designationAHRI reference: 217313579 | 17.65 | 8.50 | 28600 | 1.85 | EPA 4028882 → |
NCHC36BT5****+TDR+ furnace: NF93U070S3BF***Cold climate designationAHRI reference: 217313635 | 17.65 | 8.50 | 28600 | 1.85 | EPA 4028907 → |
NCDC42BT5****+TDR+ furnace: NF97D070T4BF***Cold climate designationAHRI reference: 217313711 | 17.65 | 9.00 | 28400 | 1.90 | EPA 4028942 → |
NCUC36BT5****+TDR+ furnace: NF97U070V3B***Cold climate designationAHRI reference: 216743579 | 17.60 | 8.50 | 28200 | 1.85 | EPA 3893277 → |
NCHC30BT5****+TDR+ furnace: NF97X040V3B***Cold climate designationAHRI reference: 216743580 | 17.60 | 8.50 | 28400 | 1.85 | EPA 3893278 → |
NCHC36BT5****+TDR+ furnace: NF97X040V3B***Cold climate designationAHRI reference: 216743584 | 17.60 | 8.50 | 28400 | 1.85 | EPA 3893282 → |
NCUC30AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 217124044 | 17.60 | 8.50 | 28600 | 1.80 | EPA 4003520 → |
NCUC30BT5****+TDR+ furnace: NF80U090V4B***Cold climate designationAHRI reference: 217124059 | 17.60 | 8.50 | 28400 | 1.85 | EPA 4003534 → |
NCUC36BT5****+TDR+ furnace: NF96U070S3B***Cold climate designationAHRI reference: 217124081 | 17.60 | 8.50 | 28400 | 1.85 | EPA 4003556 → |
NCHC30BT5****+TDR+ furnace: NF95X060S3B***Cold climate designationAHRI reference: 217124102 | 17.60 | 8.50 | 28400 | 1.85 | EPA 4003578 → |