GE Appliances / AIR-SOURCE HEAT PUMP

NS18H36HA5***

Connect · source records, page 13

386 published source records · source checked Sep 21, 2026

SEER2 range15.2–19.3BTU/Wh
HSPF2 range8.1–9.6BTU/Wh
Cooling capacity32,200–36,200BTU/h

Each efficiency range summarizes published EPA records for NS18H36HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 386 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19.3386 / 386
EER2 · BTU/Wh10–12386 / 386
HSPF2 · BTU/Wh8.1–9.6386 / 386
Cooling capacity · BTU/h32,200–36,200386 / 386
Heating capacity at 47°F / 8.3°C · BTU/h34,000–38,500386 / 386
Heating capacity at 17°F / −8.3°C · BTU/h27,000–29,600386 / 386
Heating capacity at 5°F / −15°C · BTU/h27,600–30,800386 / 386
COP at 5°F / −15°C1.8–1.95386 / 386
Equipment / loop typeHP - Split System386 / 386
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)386 / 386
Compressor stagingContinuously variable386 / 386
Connected capabilityNo386 / 386

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NCUC30AT5****+TDR+ furnace: NF80L070S3A***Cold climate designationAHRI reference: 21712404617.308.50286001.85EPA 4003521
NCUC30AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 21712404717.308.50286001.85EPA 4003523
NCUC36BT5****+TDR+ furnace: NF80D090S4B***Cold climate designationAHRI reference: 21712408717.308.50282001.90EPA 4003562
NCDC3036BT5****+TDR+ furnace: NF80D070S3B***Cold climate designationAHRI reference: 21712413817.308.50284001.85EPA 4003614
NCDC42BT5****+TDR+ furnace: NF80D090T4B***Cold climate designationAHRI reference: 21712414617.308.50282001.90EPA 4003622
NCUC30BT5****+TDR+ furnace: NF96U070V3B***Cold climate designationAHRI reference: 21717770717.308.50284001.85EPA 4006864
NCHC30BT5****+TDR+ furnace: NF96U045V3B***Cold climate designationAHRI reference: 21717771017.308.50284001.85EPA 4006868
NCHC36BT5****+TDR+ furnace: NF96U045V3B***Cold climate designationAHRI reference: 21717771217.308.50284001.85EPA 4006870
NCUC30AT5****+TDR+ furnace: NF80U045V3AF***Cold climate designationAHRI reference: 21731343417.308.50286001.80EPA 4028801
NCUC30BT5****+TDR+ furnace: NF97U070T3BF***Cold climate designationAHRI reference: 21731345517.308.50286001.80EPA 4028822
NCUC30BT5****+TDR+ furnace: NF96U045V3BF***Cold climate designationAHRI reference: 21731346617.308.50286001.85EPA 4028827
NCU[C,U]36CT5****+TDR+ furnace: NF96U090S4C***Cold climate designationAHRI reference: 21766321417.308.50286001.85EPA 4498204
NCDC36BT5****+TDR+ furnace: NF80D070S3B***Cold climate designationAHRI reference: 21790349517.308.50284001.85EPA 4515654
NCUC30BT5****+TDR+ furnace: NF96U070S3B***Cold climate designationAHRI reference: 21712405817.258.50286001.80EPA 4003535
NCUC30BT5****+TDR+ furnace: NF80U090V4BF***Cold climate designationAHRI reference: 21731348017.258.50286001.85EPA 4028795
NCUC30BT5****+TDR+ furnace: NF96U070S3BF***Cold climate designationAHRI reference: 21731344717.258.50286001.80EPA 4028819
NCDC3036BT5****+TDR+ furnace: NF97D070T4BF***Cold climate designationAHRI reference: 21731369117.258.50288001.85EPA 4028933
NCU[C,U]36CT5****+TDR+ furnace: NF80U110T3BF***Cold climate designationAHRI reference: 21766321017.258.50286001.85EPA 4498200
NCU[C,U]36CT5****+TDR+ furnace: NF93U110S4CF***Cold climate designationAHRI reference: 21766321617.258.50284001.85EPA 4498206
NCDC36BT5****+TDR+ furnace: NF97D070T4BF***Cold climate designationAHRI reference: 21790351517.258.50288001.85EPA 4515675

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →