Each efficiency range summarizes published EPA records for NS18H24HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 206 / 206 |
| EER2 · BTU/Wh | 11–12.3 | 206 / 206 |
| HSPF2 · BTU/Wh | 8.5–10 | 206 / 206 |
| Cooling capacity · BTU/h | 23,200–24,600 | 206 / 206 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,800–24,800 | 206 / 206 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,200 | 206 / 206 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–23,400 | 206 / 206 |
| COP at 5°F / −15°C | 1.75–1.85 | 206 / 206 |
| Equipment / loop type | HP - Split System | 206 / 206 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 206 / 206 |
| Compressor staging | Continuously variable | 206 / 206 |
| Connected capability | No | 206 / 206 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC30AT5****+TDR+ furnace: NF80L045S3A***Cold climate designationAHRI reference: 217123968 | 16.85 | 9.00 | 20800 | 1.80 | EPA 4003453 → |
NCUC30AT5****+TDR+ furnace: NF80U045S3A***Cold climate designationAHRI reference: 217123967 | 16.85 | 9.00 | 20800 | 1.80 | EPA 4003454 → |
NCHC30AT5****+TDR+ furnace: NF80U070S3A***Cold climate designationAHRI reference: 217124027 | 16.85 | 9.40 | 20800 | 1.85 | EPA 4003503 → |
NCUC30BT5****+TDR+ furnace: NF80U090T3BF***Cold climate designationAHRI reference: 217313239 | 16.85 | 9.00 | 20600 | 1.80 | EPA 4028722 → |
NCUC30BT5****+TDR+ furnace: NF93U030S3BF***Cold climate designationAHRI reference: 217313258 | 16.85 | 9.00 | 21000 | 1.80 | EPA 4028739 → |
NCUC30BT5****+TDR+ furnace: NF93U045S3BF***Cold climate designationAHRI reference: 217313261 | 16.85 | 9.00 | 21000 | 1.80 | EPA 4028747 → |
NCHC30AT5****+TDR+ furnace: NF80U070S3AF***Cold climate designationAHRI reference: 217313372 | 16.85 | 9.40 | 20800 | 1.85 | EPA 4028767 → |
NCHC24BT5****+TDR+ furnace: NF80L070S3B***Cold climate designationAHRI reference: 217124014 | 16.80 | 9.00 | 20800 | 1.80 | EPA 4003489 → |
NCHC24BT5****+TDR+ furnace: NF80U070S3B***Cold climate designationAHRI reference: 217124013 | 16.80 | 9.00 | 20800 | 1.80 | EPA 4003490 → |
NCDC24AT5****+TDR+ furnace: NF80D070T3A***Cold climate designationAHRI reference: 217124037 | 16.80 | 9.40 | 21000 | 1.80 | EPA 4003513 → |
NCHC24AT5****+TDR+ furnace: NF80U045V3AF***Cold climate designationAHRI reference: 217313331 | 16.80 | 9.00 | 21000 | 1.80 | EPA 4028758 → |
NCDC24AT5****+TDR+ furnace: NF80D070V3AF***Cold climate designationAHRI reference: 217313411 | 16.80 | 9.00 | 21000 | 1.80 | EPA 4028789 → |
NCHC24AT5****+TDR+ furnace: NF80X060V3A***Cold climate designationAHRI reference: 217124004 | 16.75 | 9.00 | 21000 | 1.80 | EPA 4003480 → |
NCHC24AT5****+TDR+ furnace: NF80U045S3A***Cold climate designationAHRI reference: 217124011 | 16.75 | 9.00 | 21000 | 1.80 | EPA 4003487 → |
NCHC24AT5****+TDR+ furnace: NF80L045S3A***Cold climate designationAHRI reference: 217124012 | 16.75 | 9.00 | 21000 | 1.80 | EPA 4003488 → |
NCUC30AT5****+TDR+ furnace: NF80U070V3A***Cold climate designationAHRI reference: 217123959 | 16.70 | 9.00 | 20800 | 1.80 | EPA 4003445 → |
NCUC30AT5****+TDR+ furnace: NF80L070S3A***Cold climate designationAHRI reference: 217123963 | 16.70 | 9.00 | 20600 | 1.80 | EPA 4003449 → |
NCUC30AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 217123964 | 16.70 | 9.00 | 20600 | 1.80 | EPA 4003450 → |
NCUC36AT5****+TDR+ furnace: NF80U070S3A***Cold climate designationAHRI reference: 217123983 | 16.70 | 9.00 | 20600 | 1.85 | EPA 4003468 → |
NCUC36BT5****+TDR+ furnace: NF80U070S3B***Cold climate designationAHRI reference: 217123986 | 16.70 | 9.00 | 20600 | 1.85 | EPA 4003472 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.