| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 206 / 206 |
| EER2 · BTU/Wh | 11–12.3 | 206 / 206 |
| HSPF2 · BTU/Wh | 8.5–10 | 206 / 206 |
| Cooling capacity · BTU/h | 23,200–24,600 | 206 / 206 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,800–24,800 | 206 / 206 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,200 | 206 / 206 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–23,400 | 206 / 206 |
| COP at 5°F / −15°C | 1.75–1.85 | 206 / 206 |
| Equipment / loop type | HP - Split System | 206 / 206 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 206 / 206 |
| Compressor staging | Continuously variable | 206 / 206 |
| Connected capability | No | 206 / 206 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC30BT5****+TDR+ furnace: NF98U070M3B***Cold climate designationAHRI reference: 217123971 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4003457 → |
NCUC36AT5****+TDR+ furnace: NF80U045S3A***Cold climate designationAHRI reference: 217123984 | 17.15 | 9.00 | 20800 | 1.85 | EPA 4003470 → |
NCUC36AT5****+TDR+ furnace: NF80L045S3A***Cold climate designationAHRI reference: 217123985 | 17.15 | 9.00 | 20800 | 1.85 | EPA 4003471 → |
NCHC30AT5****+TDR+ furnace: NF80L070S3A***Cold climate designationAHRI reference: 217124024 | 17.15 | 9.40 | 20600 | 1.85 | EPA 4003500 → |
NCHC30AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 217124025 | 17.15 | 9.40 | 20600 | 1.85 | EPA 4003501 → |
NCDC24BT5****+TDR+ furnace: NF97D070M3B***Cold climate designationAHRI reference: 217124040 | 17.15 | 9.40 | 20800 | 1.80 | EPA 4003516 → |
NCUC30BT5****+TDR+ furnace: NF96U070V3B***Cold climate designationAHRI reference: 217177699 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4006856 → |
NCUC36BT5****+TDR+ furnace: NF80U090T3BF***Cold climate designationAHRI reference: 217313285 | 17.15 | 9.00 | 20400 | 1.85 | EPA 4028709 → |
NCUC36BT5****+TDR+ furnace: NF93U045S3BF***Cold climate designationAHRI reference: 217313307 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4028743 → |
NCHC24BT5****+TDR+ furnace: NF80U090T3BF***Cold climate designationAHRI reference: 217313338 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4028761 → |
NCHC30BT5****+TDR+ furnace: NF80U090T3BF***Cold climate designationAHRI reference: 217313382 | 17.15 | 9.00 | 20600 | 1.80 | EPA 4028773 → |
NCUC36AT5****+TDR+ furnace: NF80L070S3A***Cold climate designationAHRI reference: 217123980 | 17.10 | 9.00 | 20400 | 1.85 | EPA 4003466 → |
NCUC36AT5****+TDR+ furnace: NF80U070T3A***Cold climate designationAHRI reference: 217123981 | 17.10 | 9.00 | 20400 | 1.85 | EPA 4003467 → |
NCUC30AT5****+TDR+ furnace: NF80U070V3AF***Cold climate designationAHRI reference: 217313234 | 17.10 | 9.00 | 20800 | 1.80 | EPA 4028720 → |
NCHC24BT5****+TDR+ furnace: NF96U030E3BF***Cold climate designationAHRI reference: 217313348 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4028726 → |
NCHC24BT5****+TDR+ furnace: NF96U030S3BF***Cold climate designationAHRI reference: 217313355 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4028729 → |
NCHC30BT5****+TDR+ furnace: NF93U030S3BF***Cold climate designationAHRI reference: 217313398 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4028783 → |
NCHC30BT5****+TDR+ furnace: NF93U045S3BF***Cold climate designationAHRI reference: 217313401 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4028784 → |
NCUC30AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 217123961 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4003447 → |
NCUC30AT5****+TDR+ furnace: NF80X060S3A***Cold climate designationAHRI reference: 217123962 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4003448 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →