NS18H24HA5***
Connect · source records, page 2
206 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS18H24HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 206 / 206 |
| EER2 · BTU/Wh | 11–12.3 | 206 / 206 |
| HSPF2 · BTU/Wh | 8.5–10 | 206 / 206 |
| Cooling capacity · BTU/h | 23,200–24,600 | 206 / 206 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,800–24,800 | 206 / 206 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,200 | 206 / 206 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–23,400 | 206 / 206 |
| COP at 5°F / −15°C | 1.75–1.85 | 206 / 206 |
| Equipment / loop type | HP - Split System | 206 / 206 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 206 / 206 |
| Compressor staging | Continuously variable | 206 / 206 |
| Connected capability | No | 206 / 206 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCHC30AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 217124022 | 17.60 | 9.50 | 20800 | 1.85 | EPA 4003498 → |
NCHC30AT5****+TDR+ furnace: NF80X060S3A***Cold climate designationAHRI reference: 217124023 | 17.60 | 9.50 | 21000 | 1.85 | EPA 4003499 → |
NCUC36AT5****+TDR+ furnace: NF80U030V3AF***Cold climate designationAHRI reference: 217313275 | 17.60 | 9.00 | 20600 | 1.85 | EPA 4028753 → |
NCHC30BT5****+TDR+ furnace: NF96U070V3BF***Cold climate designationAHRI reference: 217313408 | 17.60 | 9.00 | 20800 | 1.80 | EPA 4028788 → |
NCHC30AT5****+TDR+ furnace: NF80U070V3AF***Cold climate designationAHRI reference: 217313378 | 17.55 | 9.50 | 20600 | 1.85 | EPA 4028770 → |
NAM18V1TA5****Cold climate designationAHRI reference: 216604740 | 17.50 | 9.40 | 23400 | 1.75 | EPA 3892991 → |
NAM24E1TA5****Cold climate designationAHRI reference: 216604742 | 17.50 | 9.50 | 23000 | 1.80 | EPA 3892992 → |
NAM30V1TA5****Cold climate designationAHRI reference: 216604744 | 17.50 | 9.40 | 23200 | 1.75 | EPA 3892993 → |
NAM30E1TA5****Cold climate designationAHRI reference: 216604743 | 17.50 | 9.40 | 23200 | 1.75 | EPA 3892994 → |
NCUC36BT5****+TDR+ furnace: NF98U070M3B***Cold climate designationAHRI reference: 217123988 | 17.50 | 9.00 | 20600 | 1.85 | EPA 4003474 → |
NCUC36BT5****+TDR+ furnace: NF97U070V3B***Cold climate designationAHRI reference: 216743563 | 17.45 | 9.00 | 20600 | 1.85 | EPA 3893261 → |
NCHC24BT5****+TDR+ furnace: NF97U070V3B***Cold climate designationAHRI reference: 216743567 | 17.45 | 9.00 | 20800 | 1.80 | EPA 3893265 → |
NCUC30BT5****+TDR+ furnace: NF97X040V3B***Cold climate designationAHRI reference: 216743556 | 17.45 | 9.00 | 20800 | 1.80 | EPA 3893313 → |
NCUC30AT5****+TDR+ furnace: NF80U045T3A***Cold climate designationAHRI reference: 217123965 | 17.45 | 9.00 | 20600 | 1.80 | EPA 4003451 → |
NCUC36AT5****+TDR+ furnace: NF80X060S3A***Cold climate designationAHRI reference: 217123979 | 17.45 | 9.00 | 20800 | 1.85 | EPA 4003463 → |
NCUC36AT5****+TDR+ furnace: NF80X040S3A***Cold climate designationAHRI reference: 217123978 | 17.45 | 9.00 | 20800 | 1.85 | EPA 4003465 → |
NCHC24BT5****+TDR+ furnace: NF98U070M3B***Cold climate designationAHRI reference: 217124015 | 17.45 | 9.00 | 20800 | 1.80 | EPA 4003491 → |
NCUC36BT5****+TDR+ furnace: NF96U070V3B***Cold climate designationAHRI reference: 217177701 | 17.45 | 9.00 | 20600 | 1.85 | EPA 4006858 → |
NCHC24BT5****+TDR+ furnace: NF96U070V3B***Cold climate designationAHRI reference: 217177703 | 17.45 | 9.00 | 20800 | 1.80 | EPA 4006860 → |
NCHC30BT5****+TDR+ furnace: NF97U070V3B***Cold climate designationAHRI reference: 216743571 | 17.40 | 9.00 | 20800 | 1.80 | EPA 3893269 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →