NS15H24HA5***
Connect 2026
113 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for NS15H24HA5***. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 113 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.9 | 113 / 113 |
| EER2 · BTU/Wh | 9–9.7 | 113 / 113 |
| HSPF2 · BTU/Wh | 8.1–8.9 | 113 / 113 |
| Cooling capacity · BTU/h | 22,600–24,400 | 113 / 113 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,400–25,000 | 113 / 113 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,900–18,900 | 113 / 113 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,900–18,900 | 113 / 113 |
| COP at 5°F / −15°C | 1.8–1.9 | 113 / 113 |
| Equipment / loop type | HP - Split System | 113 / 113 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 113 / 113 |
| Compressor staging | Continuously variable | 113 / 113 |
| Connected capability | No | 113 / 113 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCHC30BT5****+TDR+ furnace: NF97U030T2BRF***Cold climate designationAHRI reference: 218493655 | 16.90 | 8.20 | 18200 | 1.80 | EPA 4636630 → |
NAM24V2TA5****Cold climate designationAHRI reference: 218380758 | 16.80 | 8.80 | 18800 | 1.80 | EPA 4591121 → |
NAM30V3TA5****Cold climate designationAHRI reference: 218380757 | 16.70 | 8.90 | 18500 | 1.90 | EPA 4591122 → |
NCUC36BT5****+TDR+ furnace: NF97X040V3B***Cold climate designationAHRI reference: 218465837 | 16.60 | 8.20 | 18100 | 1.80 | EPA 4624593 → |
NCUC36AT5****+TDR+ furnace: NF80U045T3A***Cold climate designationAHRI reference: 218465830 | 16.60 | 8.20 | 18000 | 1.80 | EPA 4624600 → |
NCUC36BT5****+TDR+ furnace: NF96U045V3BF***Cold climate designationAHRI reference: 218493593 | 16.60 | 8.20 | 18100 | 1.80 | EPA 4636673 → |
NCUC36BT5****+TDR+ furnace: NF80U090V3BF***Cold climate designationAHRI reference: 218493562 | 16.60 | 8.20 | 18000 | 1.80 | EPA 4636702 → |
NCHC30AT5****+TDR+ furnace: NF80U045T3A***Cold climate designationAHRI reference: 218465857 | 16.50 | 8.40 | 17900 | 1.90 | EPA 4624581 → |
NCHC30BT5****+TDR+ furnace: NF96U070V3BF***Cold climate designationAHRI reference: 218493691 | 16.50 | 8.10 | 18200 | 1.80 | EPA 4636599 → |
NCHC30BT5****+TDR+ furnace: NF80U070V4BF***Cold climate designationAHRI reference: 218493677 | 16.50 | 8.10 | 18100 | 1.80 | EPA 4636613 → |
NCUC36BT5****+TDR+ furnace: NF96U070V3BF***Cold climate designationAHRI reference: 218493595 | 16.50 | 8.20 | 18100 | 1.80 | EPA 4636671 → |
NCUC36AT5****+TDR+ furnace: NF80U030V3AF***Cold climate designationAHRI reference: 218493556 | 16.50 | 8.20 | 18000 | 1.80 | EPA 4636708 → |
NCHC30BT5****+TDR+ furnace: NF97X040V3B***Cold climate designationAHRI reference: 218465870 | 16.40 | 8.20 | 18200 | 1.80 | EPA 4624575 → |
NCHC24BT5****+TDR+ furnace: NF97X040V3B***Cold climate designationAHRI reference: 218465852 | 16.40 | 8.20 | 18200 | 1.80 | EPA 4624586 → |
NCUC36BT5****+TDR+ furnace: NF98U070M3B***Cold climate designationAHRI reference: 218465839 | 16.40 | 8.20 | 18000 | 1.80 | EPA 4624591 → |
NCHC30BT5****+TDR+ furnace: NF80U090V3BF***Cold climate designationAHRI reference: 218493693 | 16.40 | 8.10 | 18100 | 1.80 | EPA 4636597 → |
NCHC30BT5****+TDR+ furnace: NF96U045V3BF***Cold climate designationAHRI reference: 218493689 | 16.40 | 8.20 | 18200 | 1.80 | EPA 4636601 → |
NCHC30AT5****+TDR+ furnace: NF80U030V3AF***Cold climate designationAHRI reference: 218493649 | 16.40 | 8.40 | 17900 | 1.80 | EPA 4636636 → |
NCHC24BT5****+TDR+ furnace: NF80U090V3BF***Cold climate designationAHRI reference: 218493643 | 16.40 | 8.20 | 18100 | 1.80 | EPA 4636642 → |
NCHC24BT5****+TDR+ furnace: NF96U070V3BF***Cold climate designationAHRI reference: 218493641 | 16.40 | 8.20 | 18200 | 1.80 | EPA 4636644 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →