Fujitsu / AIR-SOURCE HEAT PUMP

FOP1542TJAYNA

F Series · source records, page 3

57 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity40,000BTU/h

Each efficiency range summarizes published EPA records for FOP1542TJAYNA. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 57 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1657 / 57
EER2 · BTU/Wh11.757 / 57
HSPF2 · BTU/Wh7.8–8.157 / 57
Cooling capacity · BTU/h40,00057 / 57
Heating capacity at 47°F / 8.3°C · BTU/h40,00057 / 57
Heating capacity at 17°F / −8.3°C · BTU/h27,000–40,00057 / 57
Heating capacity at 5°F / −15°C · BTU/h18,700–19,30056 / 57
COP at 5°F / −15°C256 / 57
Equipment / loop typeHP - Split System57 / 57
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)57 / 57
Compressor stagingTwo-stage57 / 57
Connected capabilityNo57 / 57

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FCCN4824SYTA+ furnace: FF80SV512524DZCold climate designationAHRI reference: 21668622316.008.10187002.00EPA 4009855
FCCN4824SYTA+ furnace: FF80TV510021DZCold climate designationAHRI reference: 21668622216.008.10187002.00EPA 4009856
FCCN4824SYTA+ furnace: FF80TV507521UHCold climate designationAHRI reference: 21668623316.008.10189002.00EPA 4009857
FCCN4821SYTA+ furnace: FF80SV510021UHNCold climate designationAHRI reference: 21668622816.008.10188002.00EPA 4009858
FCCN4824SYTA+ furnace: FF80TV510021UHCold climate designationAHRI reference: 21668623216.008.10188002.00EPA 4009859
FCCN4824SYTA+ furnace: FF80SV510021DZCold climate designationAHRI reference: 21668623016.008.10187002.00EPA 4009860
FCCN4824SYTA+ furnace: FF80SV510021UHUCold climate designationAHRI reference: 21668623116.008.10188002.00EPA 4009861
FCCN4824SYTA+ furnace: FF80SV510021UHSCold climate designationAHRI reference: 21668622916.008.10188002.00EPA 4009862
FCCN4821SYTA+ furnace: FF80TV407517DZCold climate designationAHRI reference: 21668623416.008.10193002.00EPA 4009863
FCCN4821SYTA+ furnace: FF96TV507021M4Cold climate designationAHRI reference: 21668632316.008.10191002.00EPA 4009864
FCCN4824SYTA+ furnace: FF96TV511524M4Cold climate designationAHRI reference: 21668632116.008.10188002.00EPA 4009865
FCCN4821SYTA+ furnace: FF96TV508521M4Cold climate designationAHRI reference: 21668632416.008.10192002.00EPA 4009866
FCCN4824SYTA+ furnace: FF96TV510021M4Cold climate designationAHRI reference: 21668633016.008.10191002.00EPA 4009867
FCCN4821SYTA+ furnace: FF96TV510021M4Cold climate designationAHRI reference: 21668632516.008.10191002.00EPA 4009868
FCCN4824SYTA+ furnace: FF96TV508521M4Cold climate designationAHRI reference: 21668631816.008.10192002.00EPA 4009869
FCCN4824SYTA+ furnace: FF96TV507021M4Cold climate designationAHRI reference: 21668646816.008.10191002.00EPA 4009870
FHRNTT4821S*YTNAAHRI reference: 21574558815.207.80EPA 3653122

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →