RD18AY36AJVC
K-SERIES · K-Series · source records, page 4
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD18AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 376 / 376 |
| EER2 · BTU/Wh | 11.7–13 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.1–10 | 376 / 376 |
| Cooling capacity · BTU/h | 31,000–32,800 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–28,200 | 376 / 376 |
| COP at 5°F / −15°C | 1.9–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | Yes | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY3621STANM+ furnace: FR801V0754A17UHCold climate designationAHRI reference: 216891492 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994917 → |
RCFY3617STANM+ furnace: FR801V0754A17UHCold climate designationAHRI reference: 216891503 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994921 → |
RCFY3621STANM+ furnace: FR98MV1005A21UPCold climate designationAHRI reference: 216891497 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994923 → |
RCFY3621STANM+ furnace: FR921V0855A21M4Cold climate designationAHRI reference: 216891505 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994929 → |
RCFY3621STANM+ furnace: FR962V0855A21M4Cold climate designationAHRI reference: 216891515 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994943 → |
RCFY3621STANM+ furnace: FR801V1005A21UHSCold climate designationAHRI reference: 216891522 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994992 → |
RCFY3621STANM+ furnace: FR97MV0855A21DHCold climate designationAHRI reference: 216891520 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994994 → |
RCFY3621STANM+ furnace: FR97MV1005A21DHCold climate designationAHRI reference: 216891525 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994997 → |
RCFY3617STANM+ furnace: FR802V1004A17UHCold climate designationAHRI reference: 216891532 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995002 → |
RCFY3617STANM+ furnace: FR801V1004A17UHCold climate designationAHRI reference: 216891546 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995015 → |
RCFY3617STANM+ furnace: FR802V0754A17DZCold climate designationAHRI reference: 216891549 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995017 → |
RCFY3621STANM+ furnace: FR951V0855A21M4Cold climate designationAHRI reference: 216891564 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3995027 → |
RCFY3617STANM+ furnace: FR802V0754A17UHCold climate designationAHRI reference: 216891568 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3995030 → |
RCFY3621STANM+ furnace: FR801V1005A21DZCold climate designationAHRI reference: 216891674 | 19.00 | 8.50 | 27400 | 2.00 | EPA 3995110 → |
RCFY3621STANM+ furnace: FR801V1004A17UHCold climate designationAHRI reference: 216891682 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995117 → |
RCFY3621STANM+ furnace: FR802V0755A21UHCold climate designationAHRI reference: 216891687 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3995123 → |
RCFY3624MTANM+ furnace: FR801V0755A21DZCold climate designationAHRI reference: 216891743 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995132 → |
RCFY3624MTANM+ furnace: FR921V0855A21M4Cold climate designationAHRI reference: 216891746 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3995135 → |
RCFY3624MTANM+ furnace: FR951V1005A21UHCold climate designationAHRI reference: 216891754 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3995143 → |
RCFY3624MTANM+ furnace: FR97MV1155A24DHCold climate designationAHRI reference: 216891759 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995147 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →