RD16AY36AJVC
F-Series · source records, page 2
40 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD16AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 40 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 40 / 40 |
| EER2 · BTU/Wh | 10–11 | 40 / 40 |
| HSPF2 · BTU/Wh | 8.5 | 40 / 40 |
| Cooling capacity · BTU/h | 32,400–34,200 | 40 / 40 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,400–33,800 | 40 / 40 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 23,400–24,000 | 40 / 40 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,200–20,200 | 40 / 40 |
| COP at 5°F / −15°C | 2.3–2.4 | 40 / 40 |
| Equipment / loop type | HP - Split System | 40 / 40 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 40 / 40 |
| Compressor staging | Continuously variable | 40 / 40 |
| Connected capability | Yes | 40 / 40 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY3621STANM+ furnace: FR972V1005A21UPSCold climate designationAHRI reference: 218719462 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704492 → |
RCFY3621STANM+ furnace: FR972V1005A21UPSCold climate designationAHRI reference: 218719461 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704493 → |
TCFY3621STANM+ furnace: FR972V0855A21UPSCold climate designationAHRI reference: 218719460 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704494 → |
RCFY3621STANM+ furnace: FR972V0855A21UPSCold climate designationAHRI reference: 218719459 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704495 → |
TCFY3621STANM+ furnace: FR972V0705A21UPSCold climate designationAHRI reference: 218719458 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704496 → |
RCFY3621STANM+ furnace: FR972V0705A21UPSCold climate designationAHRI reference: 218719457 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704497 → |
TCFY3621STANM+ furnace: FR972V0703A17UPSCold climate designationAHRI reference: 218719456 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704498 → |
TCFY3617STANM+ furnace: FR972V0703A17UPSCold climate designationAHRI reference: 218719455 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704499 → |
RCFY3621STANM+ furnace: FR972V0703A17UPSCold climate designationAHRI reference: 218719454 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704500 → |
RCFY3617STANM+ furnace: FR972V0703A17UPSCold climate designationAHRI reference: 218719453 | 16.00 | 8.50 | 20000 | 2.30 | EPA 4704501 → |
TCFY3621STANM+ furnace: FR972V0603A17UPSCold climate designationAHRI reference: 218719452 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704502 → |
TCFY3617STANM+ furnace: FR972V0603A17UPSCold climate designationAHRI reference: 218719451 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704503 → |
RCFY3621STANM+ furnace: FR972V0603A17UPSCold climate designationAHRI reference: 218719450 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704504 → |
RCFY3617STANM+ furnace: FR972V0603A17UPSCold climate designationAHRI reference: 218719449 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704505 → |
TCFY3621STANM+ furnace: FR972V0403A17UPSCold climate designationAHRI reference: 218719448 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704506 → |
TCFY3617STANM+ furnace: FR972V0403A17UPSCold climate designationAHRI reference: 218719447 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704507 → |
RCFY3621STANM+ furnace: FR972V0403A17UPSCold climate designationAHRI reference: 218719446 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704508 → |
RCFY3617STANM+ furnace: FR972V0403A17UPSCold climate designationAHRI reference: 218719445 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704509 → |
TCFY3617STANM+ furnace: FR972V0403A14UDSCold climate designationAHRI reference: 218719444 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704510 → |
RCFY3617STANM+ furnace: FR972V0403A14UDSCold climate designationAHRI reference: 218719443 | 16.00 | 8.50 | 20200 | 2.30 | EPA 4704511 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →