FWP15AZ24AJ2N
F-SERIES PLUS · VERSUS · source records, page 4
71 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for FWP15AZ24AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 71 / 71 |
| EER2 · BTU/Wh | 11.7 | 71 / 71 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 71 / 71 |
| Cooling capacity · BTU/h | 22,800 | 71 / 71 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,600–22,800 | 71 / 71 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,800–16,500 | 71 / 71 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,500–13,300 | 71 / 71 |
| COP at 5°F / −15°C | 2–2.4 | 71 / 71 |
| Equipment / loop type | HP - Split System | 71 / 71 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 71 / 71 |
| Compressor staging | Two-stage | 71 / 71 |
| Connected capability | No | 71 / 71 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFZ2417STANM+ furnace: FR951V0603A17M4AHRI reference: 214328256 | 16.00 | 8.10 | 13200 | 2.30 | EPA 3438741 → |
RCFZ2417MTANM+ furnace: FR951V0603A17UHUAHRI reference: 214328253 | 16.00 | 7.80 | 12000 | 2.00 | EPA 3438742 → |
RCFZ2417STANM+ furnace: FR801V0504A17UHSAHRI reference: 214328261 | 16.00 | 8.10 | 13100 | 2.30 | EPA 3438743 → |
RCFZ2417STANM+ furnace: FR951V0603A17UHUAHRI reference: 214328257 | 16.00 | 8.10 | 13200 | 2.30 | EPA 3438744 → |
RCFZ2417STANM+ furnace: FR951V0403A17M4AHRI reference: 214328259 | 16.00 | 8.10 | 13100 | 2.30 | EPA 3438745 → |
RCFZ2417MTANM+ furnace: FR951V0403A17UHUAHRI reference: 214328254 | 16.00 | 7.80 | 12000 | 2.00 | EPA 3438746 → |
RCFZ2417STANM+ furnace: FR921V0703A17M4AHRI reference: 214328255 | 16.00 | 8.10 | 13200 | 2.30 | EPA 3438747 → |
FRH3VZ2417STACNAHRI reference: 214664593 | 16.00 | 7.80 | 11500 | 2.10 | EPA 3543762 → |
FRH2TZ2417STANNAHRI reference: 213087949 | 15.20 | 7.80 | 12300 | 2.30 | EPA 2632353 → |
TCFZ2417STANM+ furnace: FR97MV0703A17DHAHRI reference: 213841812 | 15.20 | 8.10 | 13200 | 2.30 | EPA 2862210 → |
RCFZ2417STANM+ furnace: FR97MV0703A17DHAHRI reference: 214328241 | 15.20 | 8.10 | 13200 | 2.30 | EPA 3438721 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →