Friedrich / AIR-SOURCE HEAT PUMP

FWP15AY36AJ2N

VERSUS · source records, page 4

134 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity34,200BTU/h

Each efficiency range summarizes published EPA records for FWP15AY36AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 134 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16134 / 134
EER2 · BTU/Wh11.7134 / 134
HSPF2 · BTU/Wh7.8134 / 134
Cooling capacity · BTU/h34,200134 / 134
Heating capacity at 47°F / 8.3°C · BTU/h33,200–34,200134 / 134
Heating capacity at 17°F / −8.3°C · BTU/h23,400–33,200134 / 134
Heating capacity at 5°F / −15°C · BTU/h17,300–18,900134 / 134
COP at 5°F / −15°C2134 / 134
Equipment / loop typeHP - Split System134 / 134
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)134 / 134
Compressor stagingTwo-stage134 / 134
Connected capabilityNo134 / 134

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
RCFY3621STANM+ furnace: FR962V0603A17M4AHRI reference: 21654631315.207.80186002.00EPA 3847563 →
RCFY3621STANM+ furnace: FR962V1005A21M4AHRI reference: 21654631615.207.80185002.00EPA 3847564 →
TCFY3621STANM+ furnace: FR801V0754A17UHAHRI reference: 21654580615.207.80183002.00EPA 3847588 →
TCFY3621STANM+ furnace: FR801V0754A17DZAHRI reference: 21654581315.207.80186002.00EPA 3847590 →
TCFY3621STANM+ furnace: FR801V0704A17UHAHRI reference: 21654582015.207.80187002.00EPA 3847591 →
TCFY3621STANM+ furnace: FR801V0504A17UHNAHRI reference: 21654581515.207.80189002.00EPA 3847592 →
TCFY3621STANM+ furnace: FR801V0504A17UHSAHRI reference: 21654581815.207.80189002.00EPA 3847594 →
TCFY3621STANM+ furnace: FR921V0855A21M4AHRI reference: 21654582515.207.80186002.00EPA 3847595 →
RCFY3617STANM+ furnace: FR801V0704A17UHAHRI reference: 21654439315.207.80187002.00EPA 3847714 →
RCFY3621STANM+ furnace: FR801V0704A17UHAHRI reference: 21654599215.207.80187002.00EPA 3847780 →
RCFY3621STANM+ furnace: FR801V0504A17UHNAHRI reference: 21654598815.207.80189002.00EPA 3847781 →
RCFY3621STANM+ furnace: FR801V0504A17UHSAHRI reference: 21654599015.207.80189002.00EPA 3847783 →
RCFY3621STANM+ furnace: FR921V0855A21M4AHRI reference: 21654599715.207.80186002.00EPA 3847784 →
RCFY3617STANM+ furnace: FR962V0703A17M4AHRI reference: 21654440815.207.80184002.00EPA 3847807 →
RCFY3617STANM+ furnace: FR801V0754A17DZAHRI reference: 21654285915.207.80186002.00EPA 3847841 →
RCFY3617STANM+ furnace: FR801V0754A17UHAHRI reference: 21654286115.207.80183002.00EPA 3847842 →
RCFY3617STANM+ furnace: FR801V0503A14DZAHRI reference: 21654286815.207.80184002.00EPA 3847843 →
RCFY3617STANM+ furnace: FR951V0703A17M4AHRI reference: 21654356015.207.80184002.00EPA 3847848 →
RCFY3617STANM+ furnace: FR921V0603A17M4AHRI reference: 21654356415.207.80186002.00EPA 3847853 →
TCFY3621STANM+ furnace: FR951V0705A21M4AHRI reference: 21654589915.207.80185002.00EPA 3847924 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →