FRP17AY48AJVC
F-Series Plus · source records, page 2
221 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for FRP17AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 221 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 221 / 221 |
| EER2 · BTU/Wh | 9–11 | 221 / 221 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 221 / 221 |
| Cooling capacity · BTU/h | 44,000–45,500 | 221 / 221 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–45,500 | 221 / 221 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 39,000–40,000 | 221 / 221 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,200–37,600 | 221 / 221 |
| COP at 5°F / −15°C | 2–2.1 | 221 / 221 |
| Equipment / loop type | HP - Split System | 221 / 221 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 221 / 221 |
| Compressor staging | Continuously variable | 221 / 221 |
| Connected capability | Yes | 221 / 221 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY4824STANM+ furnace: FR921V0705A21M4SCold climate designationAHRI reference: 218328338 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620333 → |
TCFY4821STANM+ furnace: FR921V0705A21M4SCold climate designationAHRI reference: 218328337 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620334 → |
TCFY4824STANM+ furnace: FR98MV1155A24UPSCold climate designationAHRI reference: 218328336 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620335 → |
TCFY4824STANM+ furnace: FR98MV1005A21UPSCold climate designationAHRI reference: 218328335 | 16.00 | 9.50 | 37200 | 2.00 | EPA 4620336 → |
TCFY4821STANM+ furnace: FR98MV1005A21UPSCold climate designationAHRI reference: 218328334 | 16.00 | 9.50 | 37200 | 2.00 | EPA 4620337 → |
TCFY4824STANM+ furnace: FR98MV0855A21UPSCold climate designationAHRI reference: 218328333 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620338 → |
TCFY4821STANM+ furnace: FR98MV0855A21UPSCold climate designationAHRI reference: 218328332 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620339 → |
TCFY4824STANM+ furnace: FR97MV1155A24DHSCold climate designationAHRI reference: 218328331 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620340 → |
TCFY4824STANM+ furnace: FR97MV1005A21DHSCold climate designationAHRI reference: 218328330 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620341 → |
TCFY4821STANM+ furnace: FR97MV1005A21DHSCold climate designationAHRI reference: 218328329 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620342 → |
TCFY4824STANM+ furnace: FR97MV0855A21DHSCold climate designationAHRI reference: 218328328 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620343 → |
TCFY4821STANM+ furnace: FR97MV0855A21DHSCold climate designationAHRI reference: 218328327 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620344 → |
TCFY4824STANM+ furnace: FR962V1155A24M4SCold climate designationAHRI reference: 218328326 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620345 → |
TCFY4824STANM+ furnace: FR962V1005A21M4SCold climate designationAHRI reference: 218328325 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620346 → |
TCFY4821STANM+ furnace: FR962V1005A21M4SCold climate designationAHRI reference: 218328324 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620347 → |
TCFY4824STANM+ furnace: FR962V0855A21M4SCold climate designationAHRI reference: 218328323 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620348 → |
TCFY4821STANM+ furnace: FR962V0855A21M4SCold climate designationAHRI reference: 218328322 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620349 → |
TCFY4824STANM+ furnace: FR962V0705A21M4SCold climate designationAHRI reference: 218328321 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620350 → |
TCFY4821STANM+ furnace: FR962V0705A21M4SCold climate designationAHRI reference: 218328320 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620351 → |
TCFY4824STANM+ furnace: FR802V1505A24UHSCold climate designationAHRI reference: 218328319 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620352 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.