FRP17AY36AJVC
F-Series Plus · source records, page 6
242 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for FRP17AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 242 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 242 / 242 |
| EER2 · BTU/Wh | 10–11 | 242 / 242 |
| HSPF2 · BTU/Wh | 9.5 | 242 / 242 |
| Cooling capacity · BTU/h | 34,000–34,200 | 242 / 242 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–34,200 | 242 / 242 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 32,000–32,600 | 242 / 242 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,400–31,400 | 242 / 242 |
| COP at 5°F / −15°C | 2 | 242 / 242 |
| Equipment / loop type | HP - Split System | 242 / 242 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 242 / 242 |
| Compressor staging | Continuously variable | 242 / 242 |
| Connected capability | Yes | 242 / 242 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY3621STANM+ furnace: FR802V0755A21DZNCold climate designationAHRI reference: 218327932 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620691 → |
RCFY3621STANM+ furnace: FR802V0754A17UHSCold climate designationAHRI reference: 218327931 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620692 → |
RCFY3617STANM+ furnace: FR802V0754A17UHSCold climate designationAHRI reference: 218327930 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620693 → |
RCFY3621STANM+ furnace: FR802V0754A17UHNCold climate designationAHRI reference: 218327929 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620694 → |
TCFY3621STANM+ furnace: FR972V0855A21UPSCold climate designationAHRI reference: 218719288 | 17.00 | 9.50 | 25400 | 2.00 | EPA 4691795 → |
RCFY3621STANM+ furnace: FR972V0855A21UPSCold climate designationAHRI reference: 218719287 | 17.00 | 9.50 | 25400 | 2.00 | EPA 4691796 → |
TCFY3621STANM+ furnace: FR972V0705A21UPSCold climate designationAHRI reference: 218719286 | 17.00 | 9.50 | 25400 | 2.00 | EPA 4691797 → |
RCFY3621STANM+ furnace: FR972V0705A21UPSCold climate designationAHRI reference: 218719285 | 17.00 | 9.50 | 25400 | 2.00 | EPA 4691798 → |
FRH2VY3617STACNCold climate designationAHRI reference: 218159993 | 16.50 | 9.50 | 31000 | 2.00 | EPA 4620253 → |
TCFY3617STANM+ furnace: FR801V0503A14UHSCold climate designationAHRI reference: 218328148 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4619968 → |
TCFY3617STANM+ furnace: FR801V0503A14UHNCold climate designationAHRI reference: 218328147 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4619969 → |
TCFY3617STANM+ furnace: FR801V0503A14DZSCold climate designationAHRI reference: 218328146 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4619970 → |
TCFY3617STANM+ furnace: FR801V0503A14DZNCold climate designationAHRI reference: 218328145 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4619971 → |
RCFY3617STANM+ furnace: FR801V0504A17UHSCold climate designationAHRI reference: 218328144 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4619972 → |
RCFY3621STANM+ furnace: FR951V1005A21M4SCold climate designationAHRI reference: 218327993 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4619975 → |
RCFY3621STANM+ furnace: FR951V0705A21M4SCold climate designationAHRI reference: 218327989 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4619979 → |
RCFY3621STANM+ furnace: FR951V0703A17M4SCold climate designationAHRI reference: 218327988 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4619980 → |
RCFY3617STANM+ furnace: FR951V0703A17M4SCold climate designationAHRI reference: 218327987 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4619981 → |
RCFY3621STANM+ furnace: FR951V0603A17UHUCold climate designationAHRI reference: 218327986 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4619982 → |
RCFY3617STANM+ furnace: FR951V0603A17UHUCold climate designationAHRI reference: 218327985 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4619983 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →