FRP17AY24AJVC
F-Series Plus · source records, page 2
88 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for FRP17AY24AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 88 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 88 / 88 |
| EER2 · BTU/Wh | 10–11.7 | 88 / 88 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 88 / 88 |
| Cooling capacity · BTU/h | 22,200–22,600 | 88 / 88 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–22,600 | 88 / 88 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,600–19,900 | 88 / 88 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,100–18,400 | 88 / 88 |
| COP at 5°F / −15°C | 2–2.2 | 88 / 88 |
| Equipment / loop type | HP - Split System | 88 / 88 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 88 / 88 |
| Compressor staging | Continuously variable | 88 / 88 |
| Connected capability | No · Yes | 88 / 88 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY2417STANM+ furnace: FR801V0754A17UHNCold climate designationAHRI reference: 218328470 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584892 → |
TCFY2417STANM+ furnace: FR801V0754A17DZSCold climate designationAHRI reference: 218328469 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584893 → |
TCFY2417STANM+ furnace: FR801V0754A17DZNCold climate designationAHRI reference: 218328468 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584894 → |
TCFY2417STANM+ furnace: FR801V0704A17UHUCold climate designationAHRI reference: 218328467 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584895 → |
TCFY2417STANM+ furnace: FR801V0504A17UHSCold climate designationAHRI reference: 218328465 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584896 → |
TCFY2417STANM+ furnace: FR801V0504A17UHNCold climate designationAHRI reference: 218328464 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584897 → |
TCFY2417STANM+ furnace: FR801V0503A14UHSCold climate designationAHRI reference: 218328463 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584898 → |
TCFY2417STANM+ furnace: FR801V0503A14UHNCold climate designationAHRI reference: 218328462 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584899 → |
TCFY2417STANM+ furnace: FR801V0503A14DZSCold climate designationAHRI reference: 218328461 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584900 → |
TCFY2417STANM+ furnace: FR801V0503A14DZNCold climate designationAHRI reference: 218328460 | 17.00 | 9.50 | 18100 | 2.10 | EPA 4584901 → |
TCFY2417STANM+ furnace: FR98MV0703A17UPSCold climate designationAHRI reference: 218328459 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584902 → |
TCFY2417STANM+ furnace: FR98MV0603A17UPSCold climate designationAHRI reference: 218328458 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584903 → |
TCFY2417STANM+ furnace: FR97MV0703A17DHSCold climate designationAHRI reference: 218328457 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584904 → |
TCFY2417STANM+ furnace: FR97MV0603A17DHSCold climate designationAHRI reference: 218328456 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584905 → |
TCFY2417STANM+ furnace: FR962V0603A17M4SCold climate designationAHRI reference: 218328455 | 17.00 | 9.50 | 18300 | 2.10 | EPA 4584906 → |
TCFY2417STANM+ furnace: FR962V0403A17M4SCold climate designationAHRI reference: 218328454 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584907 → |
RCFY2417STANM+ furnace: FR951V0603A17M4SCold climate designationAHRI reference: 218328450 | 17.00 | 9.50 | 18300 | 2.10 | EPA 4584909 → |
RCFY2417STANM+ furnace: FR951V0403A17M4SCold climate designationAHRI reference: 218328447 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584910 → |
RCFY2417STANM+ furnace: FR921V0603A17M4SCold climate designationAHRI reference: 218328446 | 17.00 | 9.50 | 18300 | 2.10 | EPA 4584911 → |
RCFY2417STANM+ furnace: FR921V0403A17M4SCold climate designationAHRI reference: 218328445 | 17.00 | 9.50 | 18200 | 2.10 | EPA 4584912 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →