FRP15AZ18AJ2N
F-SERIES PLUS · source records, page 2
42 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for FRP15AZ18AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 42 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 42 / 42 |
| EER2 · BTU/Wh | 11.7 | 42 / 42 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 42 / 42 |
| Cooling capacity · BTU/h | 17,100 | 42 / 42 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 17,100 | 42 / 42 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 11,000–12,300 | 42 / 42 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,100–9,500 | 42 / 42 |
| COP at 5°F / −15°C | 1.9–2.2 | 42 / 42 |
| Equipment / loop type | HP - Split System | 42 / 42 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 42 / 42 |
| Compressor staging | Two-stage | 42 / 42 |
| Connected capability | No | 42 / 42 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFZ2417STANM+ furnace: FR951V0603A17M4AHRI reference: 213841767 | 15.20 | 8.10 | 9400 | 2.20 | EPA 2862292 → |
TCFZ2417STANM+ furnace: FR921V0603A17M4AHRI reference: 213841775 | 15.20 | 8.10 | 9400 | 2.20 | EPA 2862297 → |
TCFZ2417STANM+ furnace: FR951V0403A17UHUAHRI reference: 213841781 | 15.20 | 8.10 | 9500 | 2.10 | EPA 2862300 → |
TCFZ2417STANM+ furnace: FR921V0703A17M4AHRI reference: 213841776 | 15.20 | 8.10 | 9300 | 2.20 | EPA 2862301 → |
TCFZ2417STANM+ furnace: FR951V0703A17M4AHRI reference: 213841780 | 15.20 | 8.10 | 9300 | 2.20 | EPA 2862303 → |
TCFZ2417STANM+ furnace: FR951V0603A17UHUAHRI reference: 213841778 | 15.20 | 8.10 | 9500 | 2.10 | EPA 2862304 → |
TCFZ2417STANM+ furnace: FR962V0603A17M4AHRI reference: 213841790 | 15.20 | 8.10 | 9400 | 2.20 | EPA 2862307 → |
TCFZ2417STANM+ furnace: FR801V0754A17DZAHRI reference: 213841796 | 15.20 | 8.10 | 9300 | 2.20 | EPA 2862310 → |
TCFZ2417STANM+ furnace: FR801V0704A17UHUAHRI reference: 213841795 | 15.20 | 8.10 | 9300 | 2.20 | EPA 2862311 → |
TCFZ2417STANM+ furnace: FR962V0703A17M4AHRI reference: 213841792 | 15.20 | 8.10 | 9300 | 2.20 | EPA 2862314 → |
RCFZ2417STANM+ furnace: FR801V0504A17UHUAHRI reference: 214327614 | 15.20 | 8.10 | 9400 | 2.20 | EPA 3438468 → |
RCFZ2417STANM+ furnace: FR951V0603A17M4AHRI reference: 214327594 | 15.20 | 8.10 | 9400 | 2.20 | EPA 3438469 → |
RCFZ2417STANM+ furnace: FR921V0603A17M4AHRI reference: 214327598 | 15.20 | 8.10 | 9400 | 2.20 | EPA 3438470 → |
RCFZ2417STANM+ furnace: FR962V0703A17M4AHRI reference: 214327607 | 15.20 | 8.10 | 9300 | 2.20 | EPA 3438471 → |
RCFZ2417STANM+ furnace: FR962V0603A17M4AHRI reference: 214327606 | 15.20 | 8.10 | 9400 | 2.20 | EPA 3438473 → |
RCFZ2417STANM+ furnace: FR801V0754A17DZAHRI reference: 214327609 | 15.20 | 8.10 | 9300 | 2.20 | EPA 3438474 → |
RCFZ2417STANM+ furnace: FR951V0703A17M4AHRI reference: 214327603 | 15.20 | 8.10 | 9300 | 2.20 | EPA 3438476 → |
RCFZ2417STANM+ furnace: FR801V0704A17UHUAHRI reference: 214327608 | 15.20 | 8.10 | 9300 | 2.20 | EPA 3438477 → |
RCFZ2417STANM+ furnace: FR921V0703A17M4AHRI reference: 214327599 | 15.20 | 8.10 | 9300 | 2.20 | EPA 3438478 → |
RCFZ2417STANM+ furnace: FR802V0754A17DZAHRI reference: 214327615 | 15.20 | 8.10 | 9300 | 2.20 | EPA 3438480 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →