Friedrich / AIR-SOURCE HEAT PUMP

FRP15AY60AJ2N

F-SERIES · F-SERIES PLUS

17 published source records · source checked Sep 21, 2026

SEER2 range15.2BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity55,500–57,000BTU/h

Each efficiency range summarizes published EPA records for FRP15AY60AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 17 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.217 / 17
EER2 · BTU/Wh11.717 / 17
HSPF2 · BTU/Wh7.817 / 17
Cooling capacity · BTU/h55,500–57,00017 / 17
Heating capacity at 47°F / 8.3°C · BTU/h55,000–56,00017 / 17
Heating capacity at 17°F / −8.3°C · BTU/h35,400–55,00017 / 17
Equipment / loop typeHP - Split System17 / 17
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)17 / 17
Compressor stagingTwo-stage17 / 17
Connected capabilityNo17 / 17

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhRecord & comparison
FRH2TY6024STANNAHRI reference: 21541547815.207.80EPA 3624803
TCFY6021STAAM+ furnace: FR801V1005A21UHNAHRI reference: 21565754015.207.80EPA 3644802
TCFY6021STAAM+ furnace: FR801V1005A21UHSAHRI reference: 21565756315.207.80EPA 3644811
TCFY6021STAAM+ furnace: FR802V1005A21UHAHRI reference: 21565760815.207.80EPA 3645050
TCFY6024STANM+ furnace: FR802V1255A24UHAHRI reference: 21565629415.207.80EPA 3645502
TCFY6024STANM+ furnace: FR802V1005A21UHAHRI reference: 21565630815.207.80EPA 3645570
TCFY6024STANM+ furnace: FR801V1255A24UHAHRI reference: 21565631915.207.80EPA 3645572
TCFY6024STANM+ furnace: FR801V1005A21UHSAHRI reference: 21565633015.207.80EPA 3645577
TCFY6024STANM+ furnace: FR801V1005A21UHNAHRI reference: 21565635315.207.80EPA 3645581
RCFY6024STANM+ furnace: FR801V1255A24UHAHRI reference: 21654378715.207.80EPA 3847522
RCFY6024STANM+ furnace: FR801V1005A21UHNAHRI reference: 21654379615.207.80EPA 3847523
RCFY6024STANM+ furnace: FR801V1005A21UHSAHRI reference: 21654379815.207.80EPA 3847524
RCFY6024STANM+ furnace: FR802V1255A24UHAHRI reference: 21654507315.207.80EPA 3847658
RCFY6021STAAM+ furnace: FR802V1005A21UHAHRI reference: 21654468115.207.80EPA 3847830
RCFY6021STAAM+ furnace: FR801V1005A21UHSAHRI reference: 21654391415.207.80EPA 3847959
RCFY6021STAAM+ furnace: FR801V1005A21UHNAHRI reference: 21654391615.207.80EPA 3847960
RCFY6024STANM+ furnace: FR802V1005A21UHAHRI reference: 21654455615.207.80EPA 3848131

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.