FRP15AY42AJ2N
F-SERIES · F-SERIES PLUS
129 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for FRP15AY42AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 129 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 129 / 129 |
| EER2 · BTU/Wh | 11.7–12 | 129 / 129 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 129 / 129 |
| Cooling capacity · BTU/h | 40,000 | 129 / 129 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 40,000 | 129 / 129 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–40,000 | 129 / 129 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,400–19,300 | 118 / 129 |
| COP at 5°F / −15°C | 2–2.1 | 118 / 129 |
| Equipment / loop type | HP - Split System | 129 / 129 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 129 / 129 |
| Compressor staging | Two-stage | 129 / 129 |
| Connected capability | No | 129 / 129 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY4824STANM+ furnace: FR801V1255A24UHCold climate designationAHRI reference: 215655145 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3644899 → |
TCFY4821STANM+ furnace: FR802V0754A17DZCold climate designationAHRI reference: 215655185 | 16.00 | 8.10 | 19300 | 2.00 | EPA 3644932 → |
TCFY4821STANM+ furnace: FR801V1005A21UHUCold climate designationAHRI reference: 215655187 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3644933 → |
TCFY4824STANM+ furnace: FR802V1255A24UHCold climate designationAHRI reference: 215655188 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3644935 → |
TCFY4824STANM+ furnace: FR801V1005A21UHUCold climate designationAHRI reference: 215655200 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645114 → |
TCFY4821STANM+ furnace: FR802V1005A21DZCold climate designationAHRI reference: 215655210 | 16.00 | 8.10 | 18700 | 2.00 | EPA 3645122 → |
TCFY4824STANM+ furnace: FR801V1005A21DZCold climate designationAHRI reference: 215655218 | 16.00 | 8.10 | 18700 | 2.00 | EPA 3645126 → |
TCFY4821STANM+ furnace: FR802V1004A17UHCold climate designationAHRI reference: 215655216 | 16.00 | 8.10 | 19000 | 2.00 | EPA 3645127 → |
TCFY4824STANM+ furnace: FR802V1255A24DZCold climate designationAHRI reference: 215655239 | 16.00 | 8.10 | 18700 | 2.00 | EPA 3645146 → |
TCFY4821STANM+ furnace: FR802V0754A17UHCold climate designationAHRI reference: 215655241 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645147 → |
TCFY4821STANM+ furnace: FR802V1005A21UHCold climate designationAHRI reference: 215655254 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645161 → |
TCFY4821STANM+ furnace: FR802V0755A21DZCold climate designationAHRI reference: 215655261 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645166 → |
TCFY4821STANM+ furnace: FR801V1005A21UHSCold climate designationAHRI reference: 215655264 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645169 → |
TCFY4821STANM+ furnace: FR801V0754A17DZCold climate designationAHRI reference: 215655272 | 16.00 | 8.10 | 19300 | 2.00 | EPA 3645177 → |
TCFY4821STANM+ furnace: FR802V0755A21UHCold climate designationAHRI reference: 215655310 | 16.00 | 8.10 | 18900 | 2.00 | EPA 3645210 → |
TCFY4821STANM+ furnace: FR801V0704A17UHCold climate designationAHRI reference: 215655341 | 16.00 | 8.10 | 19300 | 2.00 | EPA 3645239 → |
TCFY4824STANM+ furnace: FR802V1005A21UHCold climate designationAHRI reference: 215655343 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645244 → |
TCFY4824STANM+ furnace: FR802V1005A21DZCold climate designationAHRI reference: 215655353 | 16.00 | 8.10 | 18700 | 2.00 | EPA 3645251 → |
TCFY4824STANM+ furnace: FR801V1005A21UHNCold climate designationAHRI reference: 215655362 | 16.00 | 8.10 | 18800 | 2.00 | EPA 3645259 → |
TCFY4821STANM+ furnace: FR801V0755A21UHCold climate designationAHRI reference: 215655361 | 16.00 | 8.10 | 18900 | 2.00 | EPA 3645261 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.