Friedrich / AIR-SOURCE HEAT PUMP

FRP15AY36AJ2N

F-SERIES · F-SERIES PLUS · source records, page 6

138 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity34,200BTU/h

Each efficiency range summarizes published EPA records for FRP15AY36AJ2N. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 138 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16138 / 138
EER2 · BTU/Wh11.7–12138 / 138
HSPF2 · BTU/Wh7.8138 / 138
Cooling capacity · BTU/h34,200138 / 138
Heating capacity at 47°F / 8.3°C · BTU/h33,200–34,200138 / 138
Heating capacity at 17°F / −8.3°C · BTU/h23,400–33,200138 / 138
Heating capacity at 5°F / −15°C · BTU/h17,300–18,900138 / 138
COP at 5°F / −15°C2–2.1138 / 138
Equipment / loop typeHP - Split System138 / 138
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)138 / 138
Compressor stagingTwo-stage138 / 138
Connected capabilityNo138 / 138

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
RCFY3617STANM+ furnace: FR802V0754A17DZAHRI reference: 21654471615.207.80186002.00EPA 3847836
RCFY3617STANM+ furnace: FR802V0504A17UHAHRI reference: 21654473315.207.80189002.00EPA 3847860
TCFY3621STANM+ furnace: FR921V0403A17M4AHRI reference: 21654557615.207.80186002.00EPA 3847894
TCFY3621STANM+ furnace: FR921V0603A17M4AHRI reference: 21654558415.207.80186002.00EPA 3847897
TCFY3621STANM+ furnace: FR951V1005A21M4AHRI reference: 21654558115.207.80185002.00EPA 3847898
TCFY3621STANM+ furnace: FR951V0403A17M4AHRI reference: 21654558615.207.80186002.00EPA 3847899
TCFY3621STANM+ furnace: FR951V1005A21UHAHRI reference: 21654559015.207.80185002.00EPA 3847900
TCFY3621STANM+ furnace: FR921V0703A17M4AHRI reference: 21654558815.207.80184002.00EPA 3847901
TCFY3621STANM+ furnace: FR921V1005A21M4AHRI reference: 21654559315.207.80185002.00EPA 3847902
TCFY3621STANM+ furnace: FR951V0703A17M4AHRI reference: 21654559515.207.80184002.00EPA 3847903
TCFY3621STANM+ furnace: FR951V0855A21M4AHRI reference: 21654560015.207.80186002.00EPA 3847904
TCFY3621STANM+ furnace: FR97MV1005A21DHAHRI reference: 21654561215.207.80181002.00EPA 3847905
TCFY3621STANM+ furnace: FR97MV0855A21DHAHRI reference: 21654561915.207.80181002.00EPA 3847906
TCFY3621STANM+ furnace: FR801V0504A17UHUAHRI reference: 21654562215.207.80187002.00EPA 3847907
RCFY3621STANM+ furnace: FR801V0754A17UHAHRI reference: 21654563415.207.80183002.00EPA 3847912
RCFY3621STANM+ furnace: FR801V0504A17UHSAHRI reference: 21654564515.207.80189002.00EPA 3847914
RCFY3621STANM+ furnace: FR801V0754A17DZAHRI reference: 21654564115.207.80186002.00EPA 3847916
RCFY3621STANM+ furnace: FR801V0504A17UHNAHRI reference: 21654564315.207.80189002.00EPA 3847917
RCFY3621STANM+ furnace: FR801V0704A17UHAHRI reference: 21654564815.207.80187002.00EPA 3847919
RCFY3621STANM+ furnace: FR921V0855A21M4AHRI reference: 21654565215.207.80186002.00EPA 3847920

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →